IMG-111 User Manual
ORing Industrial Networking Corp. 43
Ethernet data buffer” times out. 0 means disable. Factory default is 0.
Flush Data Buffer After:
The received data will be queuing in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "flush S2E data buffer"
timeout the data will also be sent. You can set the time from 0 to 65535
seconds
Ethernet
to
Serial
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will
be hold until the delimiters are received or the option “Flush Ethernet to
Serial data buffer” times out. 0 means disable. Factory default is 0.
Flush Data Buffer After:
The received data will be queuing in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "flushE2S data buffer"
timeout the data will also be sent. You can set the time from 0 to 65535
seconds.
Force
TX
Interval Time
Force TX interval time is to specify the timeout when no data has been
transmitted. When the timeout is reached or TX buffer is full (4K Bytes),
the queued data will be sent. 0 means disable. Factory default value is 0.
5.3.7 Service Mode
V
irtual COM Mode
In Virtual COM Mode, The driver establishes a transparent connection between host and
serial device by mapping the Port of the serial server serial port to local COM port on the host
computer. Virtual COM Mode also supports up to 5 simultaneous connections, so that
multiple hosts can send or receive data by the same serial device at the same time.
Summary of Contents for IMG-111