RDS-3086/3166G User Manual
ORing Industrial Networking Corp
28
IP address of the secondary DNS server.
G5/G6 SFP Speed
Select a speed for the SFP port.
4.2.2 Serial Setting
4.2.2.1 Serial Configuration
This page allows you to configure serial port parameters.
Label
Description
Port Alias
Enter the COM port number that modem is connected to
Interface
Choose an interface for your serial device. Available interfaces
include
RS-232, RS-422, RS-485-2W, and RS-485-4W
.
Baud Rate
Choose a baud rate in the range between 110 bps and 11520
bps
Data Bits
Choose the number of data bits to transmit. You can
configure data bits to be 5, 6, 7, or 8. Data is transmitted as a
series of five, six, seven, or eight bits (five and six bit data
formats are used rarely for specialized communications
equipment).