Battery Pack Specification 

 

Model DC1000RTXEBM 

DC1500RTXEBM DC2000RTXEBM DC3000RTXEBM 

Used with UPS Models 

1K 

1.5K 

2K 

3K 

Battery Type 

12V 9Ah 

12V 9Ah 

12V 9Ah 

12V 9Ah 

Battery Numbers 

12 

Dimensions(DxWxH) 

380 x 438 x 88 

480 x 438 x 88 

600 x 438 x 88 

Net Weight(kgs) 

17.1 

21.5 

29 

41.2 

NOTE:

 Battery pack should be used with corresponded UPS. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Orion Power Systems Service and Technical Support 

If you have any problems or questions with the UPS, call your local distributor or 
Orion Power Systems technical support at the following telephone number : 
In the United States: 

1-877-385-1654 

Please have the following information ready when you call: 
- Model number and Serial number 
- Description of failure or problem 
- Date of failure or problem 
- Customer contact information and return address   
If repair is necessary, you will be given a Returned Material Authorization 
(RMA) number. The RMA number must appear on the outside of the box 
and on the Bill Of Lading. Original packaging should be used if available.   
Systems that get damaged in transit as a result of improper packaging are 
not covered under warranty. A replacement or repair unit will be shipped, 
freight prepaid for all units under warranty. 

 

NOTE: 

For critical applications, immediate replacement may be available.   

 

 

Summary of Contents for DC1000RT

Page 1: ...Online RT RTX User Manual Online UPS 1K 1 5K 2K 3K...

Page 2: ...perating principle 4 2 3 Install the UPS 4 2 4 Setup the UPS 6 2 5 Battery Replacement 8 2 6 Battery Kit Assembly option 9 3 Operations 11 3 1 Button operation 11 3 2 LCD Panel 12 3 3 Audible Alarm 13...

Page 3: ...to UPS output sockets The UPS can be operated by any individuals with no previous experience The UPS can be operated in TN TT power distribution Connect the UPS system only to an earthed shockproof ou...

Page 4: ...e kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground...

Page 5: ...2 1 Rear panel view 1K 1 5K 2K NEMA 3K NEMA 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Input circuit breaker 5 Emergency p...

Page 6: ...onsideration the UPS is shipped out from factory without connecting battery wires Before install the UPS please follow below steps to re connect battery wires first Step 1 Step 2 Step 3 Remove front p...

Page 7: ...d external battery Tower Installation Install UPS alone Step 1 Step 2 Step 3 Install UPS and external battery NOTE When installing the UPS or battery pack with feet please keep 70mm distance from the...

Page 8: ...e also install a UL approved circuit breaker 40A between the mains and AC input in 3K model for safety operation Step 3 UPS output connection There two kinds of outputs programmable outlets and genera...

Page 9: ...Disable and enable EPO function Keep the pin 1 and pin 2 closed for UPS normal operation To activate EPO function cut the wire between pin 1 and pin 2 Step 7 Turn on the UPS Press the ON Mute button...

Page 10: ...tes before replacing batteries Note Upon battery disconnection equipment is not protected from power outages Step 1 Step 2 Step 3 Remove front panel Disconnect battery wires Pull out the battery box b...

Page 11: ...ssembled battery packs on one side of plastic shells Step 4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 3 battery kit Step 1 Remove adhesive tapes Step 2 Con...

Page 12: ...4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 6 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Step...

Page 13: ...his button at least 2 seconds to turn off the UPS in battery mode UPS will be in standby mode under power normal or transfer to bypass mode if the Bypass enable setting by pressing this button Confirm...

Page 14: ...formation Indicates the output voltage frequency or battery voltage Vac output voltage Vdc battery voltage Hz frequency Load information Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicat...

Page 15: ...voltage Vdc battery voltage Hz input frequency 3 3 Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously soundi...

Page 16: ...ut voltage is 240Vac For 100 110 115 120VAC models you may choose the following output voltage 100 presents output voltage is 100Vac 110 presents output voltage is 110Vac 115 presents output voltage i...

Page 17: ...is off Interface Setting ENA Bypass mode is enabled when UPS is off DIS Bypass mode is disabled when UPS is off Default 07 Programmable outlets enable disable Interface Setting ENA Programmable outle...

Page 18: ...table input voltage range is from 160V to 260V 170 270 flashing in turns The acceptable input voltage range is from 170V to 270V For 100 110 115 120 VAC models you may choose the following selection f...

Page 19: ...imizer When the input voltage is within setting range 3 Vo max UPS will bypass voltage to output for energy saving PFC and INVERTER are off at this mode Frequency Converter mode Rack When input freque...

Page 20: ...high 27 Bus unbalance 04 x Battery voltage too low 28 Bus short circuited 05 x Over temperature 41 x Inverter soft start fail 11 x Over load 43 Inverter voltage high 12 x 3 8 Warning indicator Warnin...

Page 21: ...icon and flashing on LCD display and alarm is sounding every second The external or internal battery is incorrectly connected Check if all batteries are connected well Fault code is shown as 27 and th...

Page 22: ...D display and alarm is continuously sounding A UPS internal fault has occurred There are two possible results 1 The load is still supplied but directly from AC power via bypass 2 The load is no longer...

Page 23: ...ler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperatur...

Page 24: ...88 peak 88 typical 90 peak Battery Mode 83 typical 86 peak 85 typical 88 peak BATTERY Battery Type 12V 9Ah 12V 9Ah 12V 9Ah 12V 9Ah Numbers 2 3 4 6 Typical Recharge Time 4 hours recover to 90 capacity...

Page 25: ...ng telephone number In the United States 1 877 385 1654 Please have the following information ready when you call Model number and Serial number Description of failure or problem Date of failure or pr...

Reviews: