Base Microscope Setup
SET UP THE BASE MICROSCOPE
A video explanation for setting up the microscope can be found at
http://www .orionwelders .
com/resources/orion-c-series-resources/
1 . Raise the microscope head to the desired
height, and then tighten it into place on
the base rod .
2 . Raise the microscope head height lock
directly underneath the microscope head,
then tighten it to the base rod .
3 . Raise the stylus rod holder to the desired
height, and then tighten it into place on
the base rod .
4 . Insert the stylus rod into the stylus rod
holder then tighten the rod into place .
5 . Insert the welding stylus into the stylus
holder on the stylus rod . Slide the stylus
into the holder until it stops then tighten
the holder .
6 . Ensure the microscope cable is plugged into the microscope shutter light ring .
7 . Plug the other end of the microscope cable into the “Microscope” port on the back of the
power supply .
CONFIGURE THE BASE MICROSCOPE
The microscope can be configured in many different ways to suit your individual preference . Orion
highly recommends configuration # 3 as the simplest to use and implement . In this configuration
the user has an unobstructed space for hand and work piece placement . This configuration also
allows the welding stylus to easily be adjusted to different angles .
1 . Microscope facing forward, work piece brought to stylus from front .
2 . Microscope head rotated 90deg from body, work piece drawn toward user to touch the stylus .
3 . Microscope head rotated 90deg from body, work piece lifted away from the user to touch the
stylus . (This drawing is the same set up as the above image listing the microscope parts )
Microscope Head
Adjustment
Microscope Focus
Microscope Head
Height Lock
Stylus Rod
Holder
Stylus Rod
Welding Stylus
Stylus Holder
Microscope
Power Switch
Microscope Light
Ring Brightness
Base Rod
Light Ring Plug
Eye Piece
Shields
Microscope Head
Swivel Lock
1.
2.
3.