background image

33

7. Specifications

Optical Tube Assembly (OTA)

Primary mirror: 

356mm (14.0") diameter 
reflective surface, low thermal 
expansion optical glass, 
parabolic, center marked

Focal length: 

1650mm

Focal ratio: 

f/4.6

Primary mirror cell: 

18-point flotation, 3 spring-
loaded collimation knobs

Secondary mirror: 

80mm minor axis, low thermal 
expansion optical glass 

Secondary mirror holder: 

4-vane spider assembly, 0.7mm 
thick spider vanes, 3 SHCS for 
tilt adjustment

Mirror coatings: 

Enhanced reflectivity (94%) 
aluminum with SiO2 overcoat

Focuser: 

Dual speed Crayford, 11:1 
fine focus knob, accepts 2" 
and 1.25" eyepieces, all metal 
construction

Optical tube design: 

Truss tube

Truss poles: 

8 total (4 truss pole assembles 
with 2 poles each), 1.0" outer 
diameter, aluminum black 
anodized, captive assembly 
hardware

Navigation knob: 

Included

Optical tube

 

material: 

Rolled steel, 1.0mm thick

Tube outer diameter: 

412mm (16.2")

OTA weight, assembled: 

69.25 lbs.

OTA weight, disassembled:  Lower tube section, 52.9 lbs. 

Upper tube section, 9.4 lbs. 
Truss pole assemblies, 6.9 lbs. 

OTA length, assembled: 

61"

OTA length, disassembled:  Lower tube section, 21.75" 

long; Upper tube section, 8.1" 
long; Truss pole assemblies, 
33.75" long

Mount

Dobsonian base: 

Collapsible design, 
CorrecTension altitude 
tensioning, side brace supports, 
carry handle

Azimuth bearing material:  Virgin Teflon on Ebony Star 

laminate

Altitude bearing material: 

Ultra-high molecular weight 
(UHMW) polyethylene on ABS 
plastic

Altitude bearing diameter:  8.0"
IntelliScope functionality: 

Computerized Object Locator 
system included, 14,000+ 
object database

Base weight: 

45 lbs., assembled

Approximate base 
dimensions: 

29" diameter x 27" tall

Accessories

2" Eyepiece: 

35mm Deep View, 2", multi-
coated, threaded for Orion filters

1.25" Eyepiece: 

10mm Sirius Plössl, 1.25", 
multi-coated, threaded for Orion 
filters

Eyepiece magnifications: 

47.1x and 165x

Finder scope: 

9x power, 50mm aperture, 
achromatic, crosshairs, 5° field 
of view

Finder scope bracket: 

Spring-loaded X-Y adjustment, 
dovetail base

Eyepiece rack: 

Holds three 1.25" eyepieces 
and one 2" eyepiece

Cooling accelerator fan: 

Included, runs off of 12V DC

Summary of Contents for 9791

Page 1: ...er Support 800 676 1343 E mail support telescope com Corporate Offices 831 763 7000 89 Hangar Way Watsonville CA 95076 Orion SkyQuest XX14i IntelliScope Truss Tube Dobsonian 9791 Providing Exceptional...

Page 2: ...2 Figure 1 The SkyQuest XX14i IntelliScope Truss Tube Dobsonian...

Page 3: ...t use of the telescope 1 Unpacking The telescope is packed in four shipping boxes as detailed below We recommend keeping the original packaging In the event that the telescope needs to be shipped to a...

Page 4: ...yepiece IntelliScope Object Locator Kit Software 9x50 Finder scope Finder scope bracket with O ring Collimation cap Hex keys x3 Washers Cooling fan mounting screws Upper tube section Lower tube sectio...

Page 5: ...r disk 1 Controller cable coil cable 1 Azimuth encoder cable shorter 1 Altitude encoder cable longer 1 Azimuth encoder spacer washer thin 1 4 outer dia 0 015 thick 4 Encoder connector board washers 3...

Page 6: ...10mm long 15mm dia 1 Insertion tube for rubber washers 3 long 3 Counterweight attachment bolts hex head 1 long black 1 Brass azimuth bushing 1 Azimuth axis bolt hex head 2 75 long 2 Fender washers 1 o...

Page 7: ...ical stop knob Fender washers x2 Altitude tensioning metal washer Vertical stop washers 2 thin 2 thick Altitude tensioning Teflon washer Hex lock nut Counterweight mounting bolts x3 Azimuth axis bolt...

Page 8: ...is hefty 14 Dob has the portability and manageability of a smaller telescope Refer to Figure 7 during base assembly When tightening screws tighten them until firm but be careful not to strip the holes...

Page 9: ...9 N R R M B C D L N O H P J E F A H I Q Q G x12 S x12 T x12 Figure 7 Exploded view of the XX14i base...

Page 10: ...liScope Object Locator kit Insert the modular jack on the azimuth encoder board E 8 into the rectangular cutout in the top baseplate D and align the encoder board so the screw lines up with the pre dr...

Page 11: ...les in each side panel The beveled end of the cylinder should be facing away from the side panel Push a bearing cyl inder screw through the side panel and thread it into the built in nut in the cylind...

Page 12: ...able should plug into the jack on the left side of the encoder connector board Figure 14 Connect one end of the altitude encoder cable the longer 20 of the two flat cables in the IntelliScope kit to t...

Page 13: ...d ing or removing one or more of the supplied thick and or thin washers Adjusting the vertical stop is required when using the IntelliScope Object Locator since the optical tube must point precisely v...

Page 14: ...least three full turns of engage ment on the shafts The mirror cell is now almost ready to be installed onto the lower tube section Before doing so check to make sure that the three mir 4 ror retaini...

Page 15: ...tion instructions For the three counterweights thread them onto the counterweight mounting bolts as far as they will go and tighten them lightly against the metal plate Figure 22 Now the upper and low...

Page 16: ...the knobs and holes line up Figure 26 When tightened the knob will clamp the truss connector against the regis tration flats on the upper truss support ring Figure 27 Repeat this for the other three...

Page 17: ...pres sure Note that the tube will not yet be properly balanced since the eyepiece and finder scope are not in place and the altitude tensioning knob has not been installed Select one of the altitude t...

Page 18: ...et and place it over the body of the finder scope until it seats into the groove in the middle of the finder Unthread the black nylon alignment screws on the bracket until the screw ends are flush wit...

Page 19: ...usly Figure 33 The other eyepiece and 1 25 adapter can be placed in the eyepiece rack until they are needed To install the 10mm Sirius Pl ssl eyepiece 1 25 instead 4 of the 2 DeepView eyepiece keep th...

Page 20: ...4i has a small adhesive ring marking its center This center mark allows you to achieve a very precise collimation you don t have to guess where the exact center of the mirror is NOTE The center ring s...

Page 21: ...head screwdriver with your other hand Figure 38 Turning the screw clockwise will move the secondary mirror toward the front opening of the optical tube while turning the screw counter clockwise will...

Page 22: ...the collimation cap is off center The tilt of the primary mirror is adjusted with three spring loaded collimation knobs on the back end of the optical tube bottom of the primary mirror cell these are...

Page 23: ...e the base to tip because of the reduced leverage In this case it is helpful to place your other hand on the base or the optical tube to help guide the tube Setting the Altitude Tension A nice feature...

Page 24: ...he weight of the eyepiece you can adjust it by tightening or loosening the drawtube ten sioning set screw on the focuser which is located just below the focus lock thumb screw Figure 33 Adjust this se...

Page 25: ...e finder scope If your general aim is accu rate the object should appear somewhere in the field of view Make small adjustments to the telescope s position until the object is centered on the finder s...

Page 26: ...lower tube section Place the dust covers on the tops of the upper and lower tube sections The telescope is now disassembled and ready to be transported Note In step 5 of Assembly of the Optical Tube...

Page 27: ...onomical Observing The SkyQuest XX14i IntelliScope Truss Tube Dobsonian pro vides prodigious capability for observing the many wonders of the heavens from the major planets to deep space nebulas and g...

Page 28: ...Moon are bright enough to see clearly even from light polluted city skies for nebulas galaxies and most star clusters the less ambient light there is to reduce contrast the better When it isn t possi...

Page 29: ...an off by unplugging the battery pack Let Your Eyes Dark Adapt Do not expect to go from a lighted house into the darkness of the outdoors at night and immediately see faint nebulas galaxies and star c...

Page 30: ...subject for observation You can see the disk of the giant planet and watch the ever changing positions of its four largest moons Io Callisto Europa and Ganymede Higher power eyepieces should bring out...

Page 31: ...rcular motion then remove any excess fluid with a fresh lens tissue Oily fingerprints and smudges may be removed using this method Use caution rubbing too hard may scratch the lens For larger lenses c...

Page 32: ...across the mirror Then rinse the mir ror under a stream of lukewarm water Any particles on the surface can be swabbed gently with a series of cotton balls each used just one time Dry the mirror in a...

Page 33: ...ower tube section 52 9 lbs Upper tube section 9 4 lbs Truss pole assemblies 6 9 lbs OTA length assembled 61 OTA length disassembled Lower tube section 21 75 long Upper tube section 8 1 long Truss pole...

Page 34: ...turned postage paid to Orion Warranty Repair 89 Hangar Way Watsonville CA 95076 Proof of purchase such as a copy of the original receipt is required This warranty does not apply if in Orion s judgment...

Reviews: