background image

 

 

IMPORTANT SAFETY INSTRUCTIONS 

(SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 
install, or operate your UPS. 
 

CAUTION! 

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and 
humidity range.) 

CAUTION! 

To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid 

exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space 
heaters or furnaces. 

CAUTION!

 Do not attach non-computer-related items, such as medical equipment, life-support 

equipment, microwave ovens, or vacuum cleaners to UPS. 

CAUTION!

 Do not plug the UPS input into its own output. 

CAUTION! 

Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any 

other liquid-containing vessels on or near the unit. 

CAUTION!

 In the event of an emergency, press the OFF button and disconnect the power cord from the 

AC power supply to properly disable the UPS. 

CAUTION!

 Do not attach a power strip or surge suppressor to the UPS. 

CAUTION!

 Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery. 

CAUTION!

 Servicing of batteries should be performed or supervised by personnel knowledgeable of 

batteries and the required precautions. Keep unauthorized personnel away from batteries. 

CAUTION! 

When replacing the batteries, use the same number and type of batteries. 

CAUTION!

 Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the 

battery or batteries. Released electrolyte is harmful to the skin and eyes. 

CAUTION! 

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

CAUTION! 

A battery can present a risk of electric shock and high short circuit current. The following 

precaution should be observed before replacing batteries: (1) Remove watches, rings, or other metal 
objects.(2) Use tools with insulated handles.(3) Wear rubber gloves and boots.(4) Do not lay tools or 
metal parts on top of batteries. (5) Disconnect charging source prior to connecting or disconnecting 
batteries terminal. 
 

INSTALLING YOUR UPS SYSTEM 

 

UNPACKING 

 
Inspect the UPS upon receipt. The box should contain the following: 
(1)UPS (2) User Manual 
 

OVERVIEW 

 
The

 

Office Pro G2 1000VA /1500VA /2000 VA provides automatic voltage regulation for inconsistent 

utility power, and battery backup during power outages. The Office Pro G2 1000VA /1500VA /2000 VA 
ensures consistent power    to your    computer system and its included software will automatically save 
your open files and shutdown your computer system during a utility power loss. 
 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 
1. 

Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS 
unit’s rated capacity. If rated unit capacities are exceeded, an overload condition may occur and 
cause the UPS unit to shut down or the circuit breaker to trip.

 

2. 

There are many factors that can affect the amount of power that your computer system will require.   
For optimal system performance keep the attached load below 80% of the UPS’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

 

1. 

Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 
8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge 
loss may occur during shipping and storage. To recharge the battery, plug the UPS into an AC 
outlet. The unit will charge in both the on and off position. 

2. 

With the UPS turned off and unplugged, connect the computer, monitor, and any equipment into the 
battery power supplied outlets. 

DO NOT plug a laser printer, copier, space heater, vacuum, 

paper shredder or other large electrical device into the battery power supplied outlets. The 
power demands of these devices will overload and possibly damage the unit.

 

3. 

Plug the UPS into a 120V , 3 wire grounded receptacle (wall outlet). Make sure the wall branch 
outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical 
demands (e.g. air conditioner, refrigerator, copier, etc.) Avoid using extension cords. 

4. 

Depress the power switch to turn the UPS on. The power on indicator light will illuminate and the 
UPS will "beep". 

5. 

If an overload is detected, an audible alarm will sound and the UPS will emit one long beep. To 
correct this, turn the UPS off and unplug at least one piece of equipment from the battery power 
supplied outlets. Wait 10 seconds. Make sure the circuit breaker is depressed and then turn the 
UPS on. 

6. 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

7. 

To store your UPS for an extended period, cover it and store with the battery fully charged. 
Recharge the battery every three months to ensure battery life. 
 

 

BASIC OPERATION 

 

FRONT PANEL DESCRIPTION 

 
 
 
 
 
 
 
 
 
 
 

Office Pro G2 1000V /1500VA /2000 VA                                         

1. 

LCD Display 

The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of 
load and battery etc. 

2. 

Power On/Off Switch 

Press the power switch to turn the UPS ON or OFF. 
Press the power switch 2 times to disable and enable the alarm beeping sound. 

3. 

Led Indicators

 

This LED is illuminated when the UPS is ON. 

 

REAR PANEL DESCRIPTION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. 

USB Port

 

This port allows connection and communication from the USB port on the computer to the UPS. 
The UPS communicates its status to the 

Power Master

 software. 

2. 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, telephone line, or network 
cable. 

3. 

Input Circuit Breaker

 

The circuit breaker provides overload protection. 

4. 

Input power cord 

Connect to utility power. NEMA 5-15P(1000VA/1500VA), NEMA 5-20P(2000VA). 

5. 

Surge Protected Outlets

 

Provides surge protection for devices that don’t require battery backup.   

6. 

Battery Backup & Surge Protected Outlets

 

Provides battery backup and surge protection. They ensure power is provided to connected 
equipment over a period of time during a power failure. 

 

REPLACING THE BATTERY 

(1000VA/1500VA/2000VA only)

 

Replacement of batteries located in an 

OPERATOR ACCESS AREA. 

 

1.  When replacing batteries, replace with the same number of the battery. 
2. 

CAUTION! 

  Risk of Energy Hazard! Before replacing batteries, remove conductive jewelry such 

as chains, wrist watches, and rings. High energy conducted through these materials could cause 
severe burns. 

3. 

CAUTION!

    Do not dispose of batteries in a fire. The batteries may explode. 

4. 

CAUTION!

    Do not open or mutilate batteries. Released material is harmful to the skin and eyes. 

It may be toxic. 

5. 

CAUTION! 

  A battery can present a risk of electrical shock and high short circuit current. The 

following precautions should be observed when working on batteries: 

1) Remove watches rings, or other metal objects. 
2) Use tools with insulated handles. 

CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE 
OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS. 
BATTERY REPLACEMENT PROCEDURE 

1. 

Turn off and unplug all connected equipment. 

2. 

Turn the UPS off and unplug it from the AC power source. 

3. 

Turn the UPS on its side. 

4. 

Remove the screws on the bottom of the front panel and

 

lay aside. 

5. 

Remove the front panel of the UPS: pull and lift it. 

6. 

Take out the battery compartment cover. 

7. 

Disconnect the battery wires from the battery. 

8. 

Remove the battery from the compartment.   

9. 

Put the battery back into the compartment.   

10.  Install the replacement battery by connecting the red wire (+) and black wire (-) to the same color 

connectors from the battery pack.   

 
 
 
 

 

Office Pro G2 1000VA/1500VA/2000VA 