OLS-32/40/46/70/8201NGB/P
14
페이지
3/30/2012
14 of 38
6. OK Acknowledgement
The acknowledgement will be sent by the display to the computer to verify that the command has been
successfully received and executed. This format for this acknowledgement is as follows:
ex) <STX>001PWR#OFF#<ETX> ( Set ID : 1 , Power Off Acknowledgement )
STX
ID1
ID2
ID3
CM1
CM2
CM3
R/W
DA1
DA2
DA3
IND
ETX
0x0f
0
0
1
P
W
R
#
O
F
F
#
0x0d
Hex
ASCII (capital letter)
Hex
7. Error Acknowledgement
The Error Values will be sent by the display to the computer to verify that the command has been
successfully received and executed.
This format for this Error Values is as follows:
ex) <STX>001PWRERROR<ETX> ( Set ID : 1 , Power Off Error )
STX
ID1
ID2
ID3
CM1
CM2
CM3
R/W
DA1
DA2
DA3
IND
ETX
0x0f
0
0
1
P
W
R
E
R
R
O
R
0x0d
Hex
ASCII (capital letter)
Hex
8. How to choose display ID number
♦ Read Set ID Number
* Attention : Read SetID Function must be only one connect Monitor (1 pc : 1 monitor)
STX
ID1
ID2
ID3
CM1
CM2
CM3
R/W
DA1
DA2
DA3
IND
ETX
0x0f
F
F
F
S
I
D
R
0
0
0
0
0x0d
Hex
ASCII (capital letter)
Hex
-
ID1 ~ ID3 : “FFF” ( Set ID )
-
DA1 ~ DA3 : “000” ( Don’t care )
Ex) <STX>FFFSIDR0000<ETX> ( Read Set ID )
Acknowledge => <STX>001SID#001#<ETX> ( Set ID : 1 )
♦ Write Set ID Number
* Attention : Write SetID Function must be only one connect Monitor (1 pc : 1 monitor)
STX
ID1
ID2
ID3
CM1
CM2
CM3
R/W
DA1
DA2
DA3
IND
ETX
0x0f
F
F
F
S
I
D
W
0
0x0d
Hex
ASCII (capital letter)
Hex
- ID1 ~
ID3 : “FFF” ( Set ID )
-
DA1 ~ DA3 : “001” ( Set ID Number )
Ex) <STX>FFFSIDR0010<ETX> ( Write Set ID : 1 )
Acknowledge => <STX>001SID#001#<ETX>