background image

5

inserting the Diagonal and Eyepiece

The SkyView Pro 80mm ED EQ comes with a camera adapt-
er attached to its focuser drawtube. Loosen the two thumb 
screws securing the camera adapter to the focuser drawtube 
and remove the camera adapter (see Figure 4). Insert the 
chrome barrel of the star diagonal into the focuser and secure 
it with the thumb screws on the drawtube. The star diagonal 
comes with a 1.25" adapter in it; this part allows for use of 
1.25" barrel diameter eyepieces in the 2" diameter diago-
nal (see Figure 5). Make sure the 1.25" adapter is secure in 
the diagonal by tightening the thumb screw on the diagonal. 
Loosen the thumb screw on the 1.25" adapter and insert the 
barrel of the 25mm eyepiece into it. Secure the eyepiece with 
the thumb screw on the 1.25" adapter. 

Your  telescope  is  now  completely  assembled  and  should 
appear as shown in Figure 1.

4. Balancing the telescope

To ensure smooth movement of the telescope on both axes 
of the equatorial mount, it is imperative that the optical tube is 
properly balanced. You will only need to balance the telescope 
with respect to the right ascension (R.A.) axis; the telescope 
should be balanced on the declination (Dec.) axis already if 
you have properly centered the 1/4"-20 mounting block on the 
optical tube relative to the tube rings.
1.   Keeping one hand on the telescope optical tube, loosenthe 

R.A. lock lever. Make sure the Dec. lock lever is locked, for  
now. The telescope should now be able to rotate freely  
about the right ascension axis. Rotate it until the counter- 
weight shaft is parallel to the ground (i.e., horizontal). 

2.   Loosen the counterweight lock knob and slide the weight  

along the shaft until it exactly counterbalances the tele- 

Figure 4. 

Before installing the 2" star diagonal, you must remove 

the camera adapter that comes attached to the telescope.

Focuser drawtube                 Thumb screws

Figure 5a. and 5b. 

To use 1.25" barrel diameter eyepieces, 

the 1.25" adapter must be installed in the 2" star diagonal. 5b. To 
use 2" eyepieces, remove the 1.25" adapter.

1.25" Barrel diameter eyepiece 

5a.

5b.

Camera adapter

2" Star diagonal

1.25" Adapter

2" Barrel diameter eyepiece 
(optional)

Finder scope

Finder scope bracket

Nylon 

alignment 

thumbscrews

Focus lock ring

Figure 3a. 

The 8x40 finder scope.

Tensioner

Figure 3b. 

Pull-back on the tensioner and slide the finder scope 

into its bracket until the O-ring is seated in the bracket ring.

Summary of Contents for SKYVIEW Pro 80mm ED EQ

Page 1: ...ED EQ Equatorial Apochromatic Refractor Telescope 9884 Customer Support 800 676 1343 E mail support telescope com Corporate Offices 831 763 7000 89 Hangar Way Watsonville CA 95076 OrionTelescopes com...

Page 2: ...knob Right ascension lock knob Right ascension slow motion control knob Counterweight shaft Counterweight Counterweight lock knob Toe saver Eyepiece 1 25 Adapter Finder scope Finder scope bracket 1 4...

Page 3: ...ppears to be missing or broken immediate ly call Orion Customer Support 800 676 1343 or email support telescope com for assistance 2 Parts List Box 1 Optical Tube Assembly and Accessories Qty Descript...

Page 4: ...the interior of the knob to connect them properly The knobs can be attached to either end of the shafts use whichever end is most convenient 9 Attach the tube mounting rings to the tube ring mounting...

Page 5: ...o the right ascension R A axis the telescope should be balanced on the declination Dec axis already if you have properly centered the 1 4 20 mounting block on the optical tube relative to the tube rin...

Page 6: ...ocusing without any image shift that typical rack and pinion designs experience If you find that the focus knobs are too tight or too loose you can make adjustments to the focuser tension by using the...

Page 7: ...turns for now Refocus the finder scope on a distant object by threading the objective lens cell in or out of the finder scope body Precise focusing will be achieved by focusing the finder scope on a...

Page 8: ...hat has superior refractive properties when compared to normal types of glass The use of this ED glass minimizes the amount of chromatic aberration resulting in a much more pleasing view when com pare...

Page 9: ...al observing More precise polar alignment is recommended for astropho tography For this we suggest using the optional polar axis finder scope From this point on in your observing session you should no...

Page 10: ...es Additional Note Regarding Focusing the Polar Axis Finder Scope The polar axis finder scope is normally focused by simply rotating the eyepiece focus ring However if after adjusting the focus ring y...

Page 11: ...lock lever and position the telescope as accurately as possible in declination so it is parallel to the R A axis as shown in Figure 1 Re tighten the lock lever 2 Loosen one of the thumb screws on the...

Page 12: ...be a major leap into the world of amateur astronomy This section is intended to get you ready for your voyages through the night sky Site Selection Pick a location away from street lights and bright y...

Page 13: ...th two high quality Sirius Pl ssl eyepieces a 25mm which gives a magnification of 24x and a 10mm which gives a magnification of 60x Other eyepieces can be used to achieve higher or lower powers It is...

Page 14: ...s most favorable at these times With good conditions you may see a salmon colored disk with some distinct dark patches and you might be able to spot a whitish polar ice cap To see surface detail on Ma...

Page 15: ...an eyepiece into the diagonal secure it with the thumb screw on the diag onal and you re ready for daytime viewing An optional altazimuth mount or a sturdy camera tripod as opposed to the SkyView Pro...

Page 16: ...ed The T ring and camera adapter are not needed since the camera is expos ing through its own lens Any camera lens with a focal length between 35mm and 400mm is appropriate On the top of one of the tu...

Page 17: ...r Then apply some cleaning fluid to a tissue never directly on the optics Wipe the lens gently in a circular motion then remove any excess fluid with a fresh lens tissue Oily fingerprints and smudges...

Page 18: ...sonville CA 95076 If the product is not registered proof of purchase such as a copy of the original invoice is required This warranty does not apply if in Orion s judgment the instrument has been abus...

Reviews: