background image

4

5

The nosepiece is fitted with filter threads. 
For light polluted skies we recommend using the Orion SkyGlow Astrophotography 
filters (Item #05559).
(Filters available through Orion, check the catalog or OrionTelescopes.com for 
more information).

8mm Wide Field lens

Attach the 8mm Wide Field lens to the SSAIO using the CS mount adapter.

Adjustable Finder Bracket 

Place the finder bracket into the dovetail finder base on your telescope and lock 
using thumb screw. 
The bracket base also features a ¼ 20 thread underneath to attach to a standard 
tripod. The bracket base can be removed from the rings to reveal another ¼ 20 
thread underneath the rings to also attach to a standard tripod. This makes using 
the camera and bracket with a standard tripod more convenient and portable 
than using a telescope with mount and tripod.
Place the SSAIO camera through the rings of the Finder Bracket and adjust the 
nylon tip screws to center view to be the same as view through telescope.
Use the reticules built into the software to aid in centering and for use as a digital 
finder.

Autoguider cable

Plug the autoguider cable into ST4 port located on rear of the SSAIO and also 
into guide port located on mount. Use PHD software for guiding.

System requirements 

Computer

The SSAIO requires a PC running Windows XP, Vista, 7 or 8.
The computer hardware should have at least the following:

•  Pentium™ III Processor
•  CD-ROM
•  Connection to the Internet
•  512MB RAM
•  Disk Space – 10GB or more is recommended
•  Video Display –16-bit color or higher, 1280 x 960 or higher is 

recommended

•  Mouse
•  USB High Speed 2.0 port

Figure 2. 

The launcher window.

Software and Driver 

Installation

Before the SSAIO can be used, soft-
ware and camera drivers must be 
installed onto your computer. 
Do not connect the camera to your 
computer before you have installed the 
software.

Software Installation

1.  Insert the CD-ROM and wait for 

the Launcher window to appear 
(

Figure 2). If you are using 

Windows Vista or Windows 7, the 
AutoPlay window will appear first, 
and then select Run autorun.exe

2.  When the launcher appears, select Install Camera Driver. Next select 

between 32bit and 64bit depending upon your target PC. Go through the 
prompts until the driver is installed.

3.  Once the camera driver is installed select Install Capture Software (which 

will install Orion AstroCap). Go through the prompts until the software is 
installed.

4.  If you intend to use the SSAIO as an autoguider, or if you wish to use the 

camera to image in a program other than Orion AstroCap, select Install 
ASCOM Camera Driver. A link is provided to also download the ASCOM 
platform which is necessary to use with the ASCOM driver.

5.  If you intend to use the SSAIO to broadcast over the internet select Install 

WDM Driver. Go through the prompts until the driver is installed.

6.  Links are also provided in order to download PHD Guiding software and post 

processing software Registax. 

Please note that to use PHD guiding or other capture software such as MaximDL 
the Camera Driver, ASCOM driver and the ASCOM platform must be installed.

Installing the Camera

1.  Once the software installation is complete from the steps above, connect the 

SSAIO to your computer’s USB port using the provided USB cable.

2.  In Windows XP a Found New Hardware Wizard will appear. Windows 7, 8 or 

Vista will automatically install the device.

3.  Windows XP will ask if you want to search for drivers and updates online. 

Select No, not this time and click Next.

Summary of Contents for StarShoot 52098

Page 1: ...Astronomy Camera 52098 instruction Manual Providing Exceptional Consumer Optical Products Since 1975 IN 508 Rev A 08 13 Customer Support www OrionTelescopes com contactus Corporate Offices 89 Hangar W...

Page 2: ...adcasting The SSAIO can even be used as a high resolution AllSky camera when used with an optional Fish Eye Lens with meteor detection and time lapse software sold separately Item 52052 All In One All...

Page 3: ...nd Driver Installation Before the SSAIO can be used soft ware and camera drivers must be installed onto your computer Do not connect the camera to your computer before you have installed the software...

Page 4: ...tware automatically 5 Windows may note that the driver has not passed Windows Logo testing This is normal Click the Continue Anyway button When the Wizard has completed click the Finish button Windows...

Page 5: ...es that can only be done when the cam era color is disabled This format is much smaller in data size and produces a much faster cap ture rate Image processing programs like MaxImDL or RegiStax can con...

Page 6: ...els will change according to the temperature so this should also be taken into consid eration Note Dark frames must match the live image exposure and gain values in order to work correctly To test you...

Page 7: ...ope is suitable for the SSAIO when imaging the planets The longer the focal length of the tele scope the larger and more detailed the images will appear Unlike deep space astro imaging you actually wa...

Page 8: ...needed for the object you are imaging Imaging Tip To speed up the frame rate and to acquire a rough focus a lit tle quicker select resolution 640x480 2x2 binning mode This will increase the frame rate...

Page 9: ...ment For best results a guide camera should also be used The longer the exposure the higher the amount of noise and hot pixels there fore automatic dark frame subtraction can be used to calibrate imag...

Page 10: ...unted on top of or beside the main imaging scope Adjustable guide scope tube rings available from Orion are rec ommended and allow you to move the guide scope around without moving the main imaging sc...

Page 11: ...PHD Guide icon and the calibration will begin The rest is auto matic Yellow crosshairs are displayed around the guide star box when the calibration starts The calibration is automatic and takes a few...

Page 12: ...auto which will find the side of drift N S Dec Algorithm Settings that attempt to smooth the declination corrections to one consistent movement and can be used to resist switching directions in Dec C...

Page 13: ...or at least five minutes and the star should begin to drift north or south 8 If the star drifts south the telescope mount is pointed too low If the star drifts north the telescope mount is pointed too...

Page 14: ...en unplug and re plug the camera into the computer s USB port Now open Orion AstroCap and select camera resolution The Live Video Window should now appear indicating re established connection between...

Page 15: ...Rate 30FPS 1280x960 44 FPS 1024x768 75FPS 800x600 106 FPS 640x480 200 FPS 320x240 A D Conversion On chip 12bit 8 bit output Thermoelectric cooling No IR Cut filter Yes Mounting 1 25 nose piece Weight...