3.7.2 Film cutter settings
The opening and closing speed of the film cutters must be set correctly. If their speed is too high, the wrap-
ping film might be damaged instead of neatly cut when the wrapping arms stop. The film cutters speed,
left (valve P4) and right (valve P5), may be reduced by turning the valve clockwise. Both cutters should be
equally set. The cutters should move softly.
Default setting: Close the valve and then open 1/2 turn.
Figure 3.6 :
Film cutter valves
Setting the speed: Turning the valve clockwise decreases the speed. Turning the valve counterclockwise
increases the speed. Adjusting the height of the cutters is normally not necessary. The film should lay on
the middle of the cutter when cut.
Film cutter rollers: Film cutter, upper position: Both rollers must roll freely. Film cutter, lower position: The
outer roller should be kept locked. This is in order to hold the film so that it is cut, not ripped. Make sure
that the knife is centred between the two rollers. Straighten the knife, if necessary. See
Figure 3.7 :
Film cutter rollers
3 SETTINGS AND HYDRAULIC ADJUSTMENTS
31
Summary of Contents for Dens-X Compactor
Page 14: ...1 6 DECLARATION OF CONFORMITY 1 GENERAL 14...
Page 103: ...8 7 MANUAL LUBRICATION CHARTS 8 7 1 The compactor 8 LUBRICATION 103...
Page 104: ...8 7 2 Feed hopper F25 8 LUBRICATION 104...
Page 105: ...8 7 3 Flexible drawbar 8 LUBRICATION 105...
Page 109: ...10 1 MAIN POWER SUPPLY E STOP SWITCHES AND ELECTRICAL CABINET 10 ELECTRICS 109...
Page 110: ...10 2 ELECTRICAL CABINET POWER SUPPLY RAIL 10 ELECTRICS 110...
Page 111: ...10 3 SENSORS AND MANUAL CONTROLS 10 ELECTRICS 111...
Page 112: ...10 4 VALVES FAN MOTORS AND PUMPS 10 ELECTRICS 112...
Page 124: ...10 9 SENSOR OVERVIEW 10 ELECTRICS 124...
Page 128: ...11 1 1 Complete diagram 11 HYDRAULICS 128...
Page 129: ...11 1 2 Wrapping table chamber and elevator control 11 HYDRAULICS 129...
Page 130: ...11 1 3 Plastic tying unit sub conveyor and feed hopper 11 HYDRAULICS 130...
Page 131: ...11 1 4 Additional feed hopper control for F25 and chamber drive 11 HYDRAULICS 131...
Page 133: ...11 2 VALVE OVERVIEW 11 2 1 Valve chart for Dens X 11 HYDRAULICS 133...
Page 137: ...12 6 3 Dimensional sketch F25 operating mode 12 SPECIFICATIONS 137...
Page 138: ...12 6 4 Dimensional sketch F25 transport mode 12 SPECIFICATIONS 138...
Page 142: ...M Maintenance 13 69 71 INDEX 142...