3.7.3 Wrapping table tilt speed
Adjusting the wrapping table tilt speed may affect the speed of the bale when rolling off the wrapping
table during bale drop. Adjusting the wrapping table tilt speed is done by turning valve P3. Clockwise
decreases the speed. Counterclockwise increases the speed. Default setting: Close the valve and then
open 3/4 turn.
NOTE: Do not set the speed too high as this might cause the bale to roll off the table uncontrollably.
Bales dropped from the wrapping table may roll more than 10 m.
3.7.4 Wrapping table ultrasonic sensor
The wrapping table ultrasonic sensor detects the bale when transported from the chamber, so that the
table accepts the bale by moving to the middle position.
3.7.5 Microsonic sensor (S1)
This type shows the read distance on an LCD. The sensor detects bales on the table.
Resetting the trigger distance and mode:
1. Press both buttons simultaneously for at least three seconds until the text ”Pro” is shown on the
LCD.
2. Press both buttons once more. The current trigger distance setting is now shown.
3. Adjust to 70 cm. (distance below 1 m shown in mm, distance above 1 m shown in cm).
4. When the desired distance is set, press both buttons simultaneously two more times and make sure
the output mode is set to “Normally closed” (symbol shown below). If not, press up or down to
change.
5. Then press both buttons simultaneously one more time until the LCD blinks ”End”.
6. Press both buttons one last time.
The sensor shows its state in its right LED. If the sensor is OK and reads nothing the LED will shine green. If
the sensor detects an object the LED will shine yellow.
3 SETTINGS AND HYDRAULIC ADJUSTMENTS
32
Summary of Contents for Dens-X Compactor
Page 14: ...1 6 DECLARATION OF CONFORMITY 1 GENERAL 14...
Page 103: ...8 7 MANUAL LUBRICATION CHARTS 8 7 1 The compactor 8 LUBRICATION 103...
Page 104: ...8 7 2 Feed hopper F25 8 LUBRICATION 104...
Page 105: ...8 7 3 Flexible drawbar 8 LUBRICATION 105...
Page 109: ...10 1 MAIN POWER SUPPLY E STOP SWITCHES AND ELECTRICAL CABINET 10 ELECTRICS 109...
Page 110: ...10 2 ELECTRICAL CABINET POWER SUPPLY RAIL 10 ELECTRICS 110...
Page 111: ...10 3 SENSORS AND MANUAL CONTROLS 10 ELECTRICS 111...
Page 112: ...10 4 VALVES FAN MOTORS AND PUMPS 10 ELECTRICS 112...
Page 124: ...10 9 SENSOR OVERVIEW 10 ELECTRICS 124...
Page 128: ...11 1 1 Complete diagram 11 HYDRAULICS 128...
Page 129: ...11 1 2 Wrapping table chamber and elevator control 11 HYDRAULICS 129...
Page 130: ...11 1 3 Plastic tying unit sub conveyor and feed hopper 11 HYDRAULICS 130...
Page 131: ...11 1 4 Additional feed hopper control for F25 and chamber drive 11 HYDRAULICS 131...
Page 133: ...11 2 VALVE OVERVIEW 11 2 1 Valve chart for Dens X 11 HYDRAULICS 133...
Page 137: ...12 6 3 Dimensional sketch F25 operating mode 12 SPECIFICATIONS 137...
Page 138: ...12 6 4 Dimensional sketch F25 transport mode 12 SPECIFICATIONS 138...
Page 142: ...M Maintenance 13 69 71 INDEX 142...