8.2.1 Refilling the oil reservoir
The grease lubrication system is sensitive to the influence of external contamination, such as dust and
dirt. Keep the cap on and refill through the male sleeve nipple (no. 11,
section 8.1.3 "Beka max grease lub-
) when refilling grease.
NOTE: Always keep the reservoir, male sleeve nipple and pump clean.
NOTE: We recommend that you purchase grease in larger containers. Pails of 20 litres/16kg’s in combination
with air or electrical operated tools for refilling. Standard grease gun with 0,5 litres cartridges might also be
used.
A grease gun for cartridges, with special nipple might be ordered as an option. Part number: 58086
8.2.2 Adjusting the amount of grease
The grease lubrication system is set to a maximum delivery of 0,29cm³/rev. However one of the pumps is
adjustable (PE120V).
Figure 8.4 :
Grease pump adjustment
Remove plug (item 2,
) to get access to adjusting screw (3). By turning the screw clockwise, the
amount is reduced. 1/2 turn on the adjusting screw reduces the grease added by 0,013cm³. Please contact
Orkel Compaction if you have any questions.
It is also possible to regulate the grease amount for the control unit. Adjustable from 100% down to 40%.
8.2.3 Bleeding the grease system
If the level in the reservoir is too low, it can be necessary to bleed the system after refilling.
1. Disconnect the plastic tube, mounted under the pressure relief valve on the pump.
2. Activate the function greaser in the control box, until there is a smooth and constant flow from the
outlet.
3. Reconnect the plastic tube to its original position.
8 LUBRICATION
95
Summary of Contents for MP2000-X
Page 14: ...1 6 DECLARATION OF CONFORMITY 1 GENERAL 14...
Page 98: ...8 6 4 Gearbox and gears for hydraulic motors Gear oil Renolin unisyn CLP 220N 8 LUBRICATION 98...
Page 99: ...8 7 MANUAL LUBRICATION CHARTS 8 7 1 The compactor 8 LUBRICATION 99...
Page 100: ...8 7 2 Feed hopper F10 8 LUBRICATION 100...
Page 101: ...8 7 3 Telescopic drawbar 8 LUBRICATION 101...
Page 105: ...10 1 MAIN POWER SUPPLY E STOP SWITCHES AND ELECTRICAL CABINET 10 ELECTRICS 105...
Page 106: ...10 2 ELECTRICAL CABINET POWER SUPPLY RAIL 10 ELECTRICS 106...
Page 107: ...10 3 SENSORS AND MANUAL CONTROLS 10 ELECTRICS 107...
Page 108: ...10 4 VALVES FAN MOTORS AND PUMPS 10 ELECTRICS 108...
Page 120: ...10 9 SENSOR OVERVIEW 10 ELECTRICS 120...
Page 124: ...11 1 1 Complete diagram 11 HYDRAULICS 124...
Page 125: ...11 1 2 Wrapping table chamber and elevator control 11 HYDRAULICS 125...
Page 128: ...11 2 VALVE OVERVIEW 11 2 1 Valve chart for MP2000 X 11 HYDRAULICS 128...
Page 132: ...12 6 3 Dimensional sketch F10 operating mode 12 SPECIFICATIONS 132...
Page 133: ...12 6 4 Dimensional sketch F10 transport mode 12 SPECIFICATIONS 133...
Page 137: ...M Maintenance 13 65 67 INDEX 137...