Proceed as follows:
1.
Make sure the tools and equipment set out in Figure 6.11
are available, and ensure the larger shackle of the lifting
beams is attached to the top slings, facing upwards. The
smaller shackle is facing downward, attached to the
slings or chains. Hook the top slings on the crane hook.
1
Top slings
2
Lifting beam
2.1
Larger lifting beam shackle
2.2
Smaller lifting beam shackle
3
Bottom slings or chains*
4
Universal-head hooks (DEHA KA-type**)
* Slings or chains, in accordance with the detailed study of the handling
process.
** The tank and body may require different universal head hooks.
Figure 6.11.
Fastening tools set
2.
Couple the eight universal-head hooks to the body's
DEHA-type anchors, as shown in Figure 6.12.
Figure 6.12.
Correct coupling method using DEHA hooks
3.
Lift and position the
pfu
body using the crane.
Figure 6.13.
Lifting and positioning the
pfu
body
Before positioning the body on the tank, follow the
instructions in section “8.5. Assembly process for
enclosures with separate body and tank.”.
4.
Once the
pfu
body is in place, uncouple the universal-
head hooks from the body's DEHA anchors.