10
Operation failed
flashes
-
-
3x beep
Exit from the programming mode
flashes
-
-
One beep
Door opening
-
bright
-
One beep
Alarm
flashes
-
-
Alarm
fig.1 Standard wiring diagram
fig. 2 Additional wiring diagram
Detailed programming manual
User settings
Enter the programming mode.
* Main code #
123456 is the default main code.
Exit the programming mode.
*
Change the main code.
0 New code # New code #
The main code is an arbitrary number consisting of 6 digits
Working mode settings:
Standard operation mode (standalone mode)
Wiegand reader mode
7 7 #
default setting
7 8 #
Add fingerprint user
Automatic assignment of user ID number
(the device assign next available user ID number)
1 Scan fingerprint Scan fingerprint Scan fingerprint
User ID numbers:
- Fingerprint user ID: 0~98
- Common user ID (card, PIN code): 100~987
- Main user ID: 99
- Panic user ID: 988, 989