INSTALLATION MANUAL / USER MANUAL
REMOTE CONTROL PANEL RC102
PAGE: 7
JUL 18/2022
© 2022 Orolia S.A.S. All rights are strictly reserved.
(2) Connection of RCP bundle to ELT
Refer to Figure 4: Wiring of 2-wire bundle between RC102 and ELT
CAUTION: RC102 can be connected only to KANNAD 406 AF-
COMPACT ELT transmitter P/N S1840501-01 at amendment equal
or higher than M or to any KANNAD 406 AF COMPACT ER P/N
S1840501-04.
Solder the DIN12 connector or Programming Dongle on the other side
of the bundle (pins K and M):
• Connect the wire from M of PCB (3a) to pin M of DIN12 connector;
• Connect the wire from K of PCB (3a) to pin K of DIN12 connector.
• Stuck the "CAUTION label" (5) on the cable bundle close to the DIN12
connector.
Perform an RCP test (
Refer to D. RCP operational tests, page 12
Figure 4: Wiring of 2-wire bundle between RC102 and ELT