26
Mounting a TV/Artwork
Ortal’s Cool Wall Technology is a technique that reduces the convective heat from the fireplace and prevents heat buildup inside the
fireplace chase, mitigating any damage that may result from the wall reaching high temperatures. Ortal’s Cool Wall system enables
the option of safely installing artwork, a TV, or other similar electronic components above the fireplace by reducing the wall
temperature above the fireplace.
Location
Wall Temperature
0-6 inches above fireplace
100˚F
-
120˚F
6-12 inches above fireplace
90˚F
-
100˚F
12 inches above fireplace
80˚F
-
90˚F
Required minimum clearance between bottom edge of TV or other similar device or
artwork and top of fireplace viewing area is 12 inches.
Maintain the following general requirements to mount a TV or artwork above the fireplace and prevent heat damage:
Mount the TV or artwork a minimum of
12 inches
above the top of the fireplace viewing area.
TV wires must be routed through framing and cannot pass through the fireplace chase.
The decision to install a television above the fireplace is up to the discretion of the owner. TV and art manufacturers may specify that
their product should not be installed on, near or above a heat source. Ortal will not be held liable for any adverse effects on a TV,
artwork or other equipment located near the fireplace. It is the owner’s responsibility to verify that their TV or artwork can withstand
the wall temperatures as outlined in the above wall temperature chart.
The following diagrams can be used as a guide for customers who do decide to locate their TV and artwork above their fireplace.
These drawings illustrate ways of reducing the amount of heat impact to the area surrounding the fireplace.
Flush Mounted TV/Artwork
NOTE: Vent clearances must be maintained. See “Vent Clearances” section for details.
Summary of Contents for Clear 130 LS
Page 53: ...53 Wiring Diagram Screen Fireplace with Interior Lighting...
Page 54: ...54 Wiring Diagram Screen Fireplace with Interior Lighting and Ortal Power Vent...
Page 55: ...55 Wiring Diagram Double Glass Fireplace...
Page 56: ...56 Wiring Diagram Double Glass Fireplace with Interior Lighting...
Page 57: ...57 Wiring Diagram Double Glass Fireplace with Interior Lighting and Ortal Power Vent...
Page 58: ...58 Carbon Monoxide Detector Wiring Diagrams CO Kit Wiring Diagram Screen Fireplace...
Page 59: ...59 CO Kit Wiring Diagram Double Glass Fireplace...