60
Home Automation Wiring Diagram
Use the following wiring diagram to connect fireplace control a hardwired home automation system.
Contacts Options/Operation
Ignition:
Close contact 1 and 3 simultaneously for 1 second. Fireplace automatically goes to high after ignition.
Up Flame:
Close contact 1. The contact needs to be closed for 12 seconds to turn the motor from end-stop to end-stop.
Down Flame:
Close contact 3. The contact needs to be closed for 12 seconds to turn the motor from end-stop to end-stop.
Off:
Close contacts 1, 2, and 3 simultaneously for 1 second.
Mode of Operation:
The external source provides ON and OFF operation only. The Timer/Thermostat handset provides all
other functions.
NOTICE:
The Timer/Thermostat handset in Thermostatic Model controls the room temperature even if the fire is turned on
by the external source. If the handset is in Manual Mode, the fire will go to High Fire in the next cycle of external operation.
NOTE: This wiring diagram is for hardwired home automation systems only and will not connect the fireplace to a
wireless system.
Interior Design Media
Ortal offers interior media options such as stones, glass, logs and embers that can provided with the fireplace. This section provides
guidelines for safe placement of media. It is crucial that the placement guidelines outlined below are followed as a large portion of
flame quality issues are caused by improper media setup.
NOTE: This section does not apply to Wilderness series fireplaces. Please see separate model-specific Log Placement
Guide for details. This will be included with the Wilderness fireplace log set.
WARNING: Only media provided by Ortal is permitted for use in the fireplace.
WARNINGS: INSTALLING AND HANDLING MEDIA
•
DO NOT
install the interior design media until fireplace installation is complete, the gas line is connected and tested for
leaks, and initial burner operation has been inspected and approved.
•
Media materials get very hot and will remain hot more than an hour after gas supply is turned off. Handle media only
when materials are cool.
•
If media is not installed according to the installation instructions, flame impingement and improper combustion may
occur and result in soot and/or excessive production of carbon monoxide (CO). Carbon monoxide is a toxic, colorless,
and odorless gas.
WARNING: The fireplace is NOT designed to burn wood. Any attempt to do so could cause irreparable damage to the
fireplace and may result in property damage, personal injury and/or loss of life.
Summary of Contents for Clear 130 LS
Page 53: ...53 Wiring Diagram Screen Fireplace with Interior Lighting...
Page 54: ...54 Wiring Diagram Screen Fireplace with Interior Lighting and Ortal Power Vent...
Page 55: ...55 Wiring Diagram Double Glass Fireplace...
Page 56: ...56 Wiring Diagram Double Glass Fireplace with Interior Lighting...
Page 57: ...57 Wiring Diagram Double Glass Fireplace with Interior Lighting and Ortal Power Vent...
Page 58: ...58 Carbon Monoxide Detector Wiring Diagrams CO Kit Wiring Diagram Screen Fireplace...
Page 59: ...59 CO Kit Wiring Diagram Double Glass Fireplace...