background image

General 

 

Safety Information and Warnings  

 WARNING: REVIEW ALL WARNINGS 

Be sure to review all safety warnings and installation guidelines contained in this manual and the applicable Ortal fireplace installation 

manual. Before installing Heat Control System, read and understand all instructions. Consider installation location, venting pathway, 

clearances, structural requirements, framing and finish materials, and local codes. ALL warnings and instructions apply to all products 

manufactured and distributed by Ortal. 

 WARNING: FOR USE WITH ORTAL-MANUFACTURED FIREPLACES ONLY 

The Heat Control System is authorized for use with Ortal manufactured fireplaces only. Do not attempt to use with a different 

manufacturer’s product. 

 WARNING: ELECTRICAL GROUNDING 

All electrical connections must be properly installed, insulated, and secured to avoid potential 

ELECTRICAL SHOCK 

and 

FIRE 

HAZARD

 and malfunction of the system. Consult local building code requirements. In the absence of local codes, refer to the National 

Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1. 

 WARNING: MATERIAL USAGE 

All materials and objects used to carry out the installation must be certified/approved or specified by Ortal and are suitable for use. 

Do NOT install the system with different materials or objects than those approved for installation by Ortal.  

 WARNING: INSTALLATION AND SERVICE 

Installation and repairs on the fireplace, Heat Control System, and vent system must be done by an Ortal-authorized qualified installer 

service agency or gas supplier. If these components are not installed by an Ortal-authorized dealer/installer, the warranty of all 

components will be void and Ortal will not be responsible for any damage caused by improper installation. The fireplace should be 

inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive 

lint from carpeting, bedding material, etc. Control compartments, burners and circulating air passageways of the fireplace must be 

kept clean. Any alteration to the product can cause soot or carbon to form and may result in damage. This damage and any other 

damage that results from not following the instructions outlined in this manual is not the responsibility of Ortal. 

 WARNING: HEAT BARRIER 

A barrier designed to reduce the risk of burns from hot viewing glass is provided with this fireplace and shall be installed. The fireplace 

MUST not be used without the heat barrier in place. If the barrier becomes damaged, the barrier shall be replaced with the 

manufacturer’s barrier for this fireplace. 

Any safety screen, guard, or barrier removed for servicing the fireplace must be 

replaced before operating. 

 WARNING: FIREPLACE TEMPERATURE 

Due to hot temperatures, the fireplace should be located out of traffic and away from furniture and draperies.  

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing 

ignition. Clothing or other flammable material should not be placed on or near the fireplace. 

Young children should be carefully 

supervised when they are  in the same room as the fireplace

. Toddlers, young children, and others may be susceptible to 

accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a 

fireplace or stove, install an adjustable safety gate to keep toddlers, young children, and other at-risk individuals out of the room and 

away from hot surfaces. 

 WARNING: GLASS HANDLING 

Only an Ortal certified installer is authorized to remove the glass using a suction cup supplied by Ortal. 

 WARNING: INSTALLATION AND OPERATION 

The fireplace and accompanying components must be installed as an OEM installation in manufactured homes (USA only) or an 

aftermarket permanently located, or a mobile home, where not prohibited by local codes.  The fireplace must be installed in 

accordance with the Manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 

3280, in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada. 

Exceeding the 

restrictions imposed in these instructions may result in a fire or explosion, causing property damage, personal injury, or 

loss of life. Ortal will not be responsible for any damage caused by improper installation. Do not store or use gasoline or 

other flammable vapors and liquids near this fireplace. 

 WARNING: LOCAL CODES 

Local codes and building requirements take precedence over all requirements stated in this manual. Consult the local authority having 

jurisdiction to ensure all local codes and requirements are followed. 

 

 

Summary of Contents for Heat Control System

Page 1: ...Ortal Installation Manual Heat Control System V1 Installation and Operation Manual Heat Control System ...

Page 2: ...the responsibility of Ortal WARNING HEAT BARRIER A barrier designed to reduce the risk of burns from hot viewing glass is provided with this fireplace and shall be installed The fireplace MUST not be used without the heat barrier in place If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this fireplace Any safety screen guard or barrier removed for se...

Page 3: ...________________ 8 Prior to Installation 8 Installation Procedure 9 System Setup 13 Air Ducting _________________________________________________________________________ 16 Duct Requirements 16 Duct Termination 16 Electrical___________________________________________________________________________ 16 Electrical Requirements 16 Wiring Diagrams 16 Operation _________________________________________...

Page 4: ...xtracts heat from the chase via two heat collector boxes and ducts it to the chosen location see figure 2 below Figure 2 Heat Control System is On When the system is off the heat is directed into the room via the heat release see figure 3 below Figure 3 Heat Control System is Off This feature is optional and is not required for the use and operation of any Ortal manufactured fireplace It is approv...

Page 5: ...and Curve Island 130 75x65 Curve 75x65 Curve TN Units that are framed into a wall only without a hood NOTE The Heat Control System cannot be used with Ortal 40H70 models 60x80 models stand alone Curves and Island or wall mounted Stand Alone fireplaces This system designed for use with Ortal manufactured fireplaces only It is not permitted for use with fireplaces made by other manufacturers or for ...

Page 6: ...ndard Fan Max Flow Rate 196 CFM Noise Level 56 dba at 1 meter from fan Dimensions Clearances NOTE 2 inch clearance is to any building material No additional air space is required beyond the 2 inch clearance ...

Page 7: ...OTE When determining installation location take note that the duct connections on the fan are set on a 90 angle See Premium Fan Airflow Direction section for details Clearances NOTE 2 inch clearance is to any building material No additional air space is required beyond the 2 inch clearance ...

Page 8: ...lace Optimal duct length is 90 feet or less Total duct length must not exceed 120 feet The Heat Control System must be installed in an interior space and can terminate either to an interior or exterior space NOTES The system is designed to remove heat from the chase and has no impact on radiant heat released from the fireplace glass Depending on local code make up air may need to be supplied to th...

Page 9: ...4 Position and connect T Connector to Insulated Air Ducting using a minimum of 3 self tapping screws per connection 5 Connect Insulated Air Ducting to the Heat Control Fan using one Hose Clamp per connection 6 Position and secure Heat Collector Boxes to the front wall inside the fireplace chase using a minimum of 4 screws per box 7 Connect Insulated Air Ducting to each Heat Collector Box using a m...

Page 10: ... or narrow side of the fan a Place the fan on a flat concrete wood surface or wood studs Position it according to air flow direction Air Flow Direction NOTE Fan can be installed oriented horizontally or vertically Step 2 Attach the fan to a mounting area via the mounting brackets Securely fasten fan to the surface with 6 screws in provided holes 3 on each side as shown in figure below ...

Page 11: ...n s inlet and outlet pipe connections when determining installation location The duct connections are set 90 to each other The air inlet connection is on the wide side of the fan and the air outlet is on the narrow side Step 1 Connect the mounting brackets to the fan The brackets can be attached on either the wide option 1 or narrow option 2 side of the fan Wide Orientation Attach brackets to the ...

Page 12: ...e fan to attach brackets as shown in figure below Step 2 Affix the fan to a mounting area via the mounting brackets Mounting area must be constructed to support the weight of the fan 52 lbs 23 5 kg Installation requires ten screws with 10mm diameter not included Wide Orientation Narrow Orientation ...

Page 13: ... note that the distances in these diagrams are exact measurements and are not maximums or minimums For example the top of the heat collectors should be located exactly 4 inches below the bottom of the heat release Frame the fireplace chase to the minimum framing values as stated in the applicable Ortal fireplace installation manual NOTE The bullet pointed statements above are recommendations and a...

Page 14: ...14 Series 110 130 Wilderness 44H Wilderness TR42 Traditional 90 110 ...

Page 15: ...15 Series 150 170 Series 200 250 ...

Page 16: ...ter must allow for minimum 28 square inches of net free air space Clearances No clearance requirements Check with local code for approved components and clearances if any Electrical WARNINGS Electrical connections should be completed by a certified electrician and in accordance with local building codes Disconnect the power supply before servicing any electrical components Electrical Requirements ...

Page 17: ...17 Wiring Diagram Screen Fireplace Wiring Diagram Screen Fireplace with Interior Lighting and Ortal Power Vent ...

Page 18: ...18 Wiring Diagram Double Glass Fireplace ...

Page 19: ...System is designed to operate in sync with the Ortal fireplace To operate the fireplace and Heat Control System together ensure the Heat Control System wall switch is in the on position Turn the fireplace on The system will turn on and off with the fireplace The wall switch should remain in the on position to keep the system s connection to the fireplace open To operate the fireplace without the H...

Page 20: ... Ortal 2020 Version 1 December 2020 SKU KPMANUALHSUS Ortal USA 8421 Canoga Ave Canoga Park CA 91304 T 818 238 7000 F 818 678 0541 info ortalheat com www ortalheat com ...