TERMINATION CAP NOTE: Low Profile Vertical Termination Cap and Sconce Horizontal Termination Cap can negatively
impact flame appearance and are not recommended for use with the fireplace.
Allowable Maximum Horizontal Runs
Series 40-75
(includes 31H)
Series 110-130
Series 150-170
Series 200
Series 250
V minimum = 0 ft
V minimum = 3 ft
V minimum = 3 ft
V minimum = 6 ft
V minimum = 6 ft
Vertical
(V)
Max
Horizontal
(H)
Vertical
(V)
Max
Horizontal
(H)
Vertical
(V)
Max
Horizontal
(H)
Vertical
(V)
Max
Horizontal
(H)
Vertical
(V)
Max
Horizontal
(H)
0 ft
6 ft
N/A
N/A
N/A N/A
N/A
N/A
N/A
N/A
1 ft
12 ft
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3 ft
21 ft
3
ft
12
ft
3 ft
9 ft
N/A
N/A
N/A
N/A
6 ft
24 ft
6 ft
24 ft
6 ft
18 ft
6 ft
18 ft
6 ft
3 ft
9 ft
30 ft
9
ft
30
ft
9 ft
30 ft
9 ft
19 ft
9 ft
8 ft
12 ft
30 ft
12 ft
30 ft
12 ft
30 ft
12 ft
19 ft
12 ft
11 ft
15 ft
24 ft
15 ft
30 ft
15
ft
30
ft
15 ft
19 ft
15 ft
12 ft
18 ft
21 ft
18 ft
27 ft
18 ft
30 ft
18 ft
19 ft
18 ft
12 ft
21 ft
18 ft
21 ft
24 ft
21
ft
27
ft
21 ft
19 ft
21 ft
10 ft
24 ft
15 ft
24 ft
21 ft
24 ft
24 ft
24 ft
19 ft
24 ft
8 ft
27 ft
12 ft
27 ft
21 ft
27
ft
21
ft
27 ft
19 ft
27 ft
7 ft
30 ft
12 ft
30 ft
21 ft
30 ft
21 ft
30 ft
19 ft
30 ft
5 ft
33 ft
12 ft
33 ft
21 ft
33
ft
15
ft
33 ft
19 ft
33 ft
4 ft
36 ft
4 ft
36 ft
12 ft
36 ft
15 ft
36 ft
19 ft
36 ft
0 ft
44 ft
0 ft
44 ft
0 ft
44 ft
0 ft
44 ft
0 ft
N/A
N/A
CHART NOTE: Do not include the space elbows take up when calculating your vertical and horizontal distances.