ELECTRICAL CONNECTIONS

Energy Recovery Ventilators

MODEL

 

OD

-ERV 150AC

Instruction Manual

1-888-543-6473
1-888-541-6474

13376 Comber Way 

Surrey BC V3W 5V9

info@ortechindustries.com 
www.ortechindustries.com

375 Admiral Blvd

 

Missis

s

auga

ON L5T 2N1

Optional Connections:

The unit has an optional terminal block for 24V AC HVAC/AHU blower integration.
The user can connect the HVAC/AHU 24V AC dry contact relay to the terminal block so that when the ERV is operating, the HVAC/AHU blower 
operates to help distribute the fresh air through the existing ductwork if needed.

The unit has an optional terminal block for a MANUAL OVERRIDE SWITCH (MOS) connection.

 Connect an ON/OFF switch to the terminal block to 

manually switch the unit to high speed. When the switch is off, the unit returns to the low speed operation per the OA, RA, and T knobs.
The optional terminal block is not required for the unit.

LED INDICATOR LIGHT FAULT DESCRIPTION

SERVICE PARTS

Summary of Contents for OD-ERV 150AC

Page 1: ...rces of hazardous air such as auto exhausts 8 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment is located take steps to assure that combustion air supply is not affected Follow the heating equipment manufacturer s requirements and the combustion air supply requirements of applicable codes and standards 9 When cutting or drill...

Page 2: ...he energy exchange core stays clean even if the core faces are covered with dust CAUTION DO NOT WASH THE ENERGY EXCHANGE CORE The energy exchange core can be replaced but is expensive The core is secured to the unit by the core latch when the unit is installed as installation B If the core latch is disengaged the core can fall out causing damage or injury if not prepared after the door swinging do...

Page 3: ... check cycle The orange L2 LED indicator light will illuminate continuously The check cycle will run the RA fan for 5 minutes at full speed every 15 minutes 25 of every hour in order to minimize frost on the core and meet code requirements The OA fan will not run during this check cycle The HVAC AHU blower if connected will NOT run during this check cycle to prevent cycling The MOS will still boos...

Page 4: ...tion of the HVAC system in a residence the speed controls should be re calibrated for optimum performance If the residence undergoes significant structural changes such as an addition to the home the unit should also be re calibrated If optional MERV 13 filters are installed recalibration is also required The unit provide the ability to deliver completely balanced airflows or to modify them as des...

Page 5: ...nit in an attic or other unconditioned space all of the unit s ductwork that is located in the attic MUST be insulated Use at least R 6 insulation INSTALLATION GUIDE CAUTION RISK OF INJURY WHEN LIFTING AND INSTALLING UNIT OVERHEAD Get a helper and wear eye protection and gloves Locate the unit for the simplest duct layout and connections Note that the door is equipped with hinges For the homeowner...

Page 6: ...a hallway or stairway rather than in a sitting area If you want to get fresh air into specific room with high occupancy you can split up the fresh air supply For Houses WITH Forced air Heating and Cooling Systems see Fig 1 Fig 3 and Fig4 Most units are installed with the fresh air duct connected directly to a return duct for the main heating and cooling system Make sure to connect the fresh air du...

Page 7: ...mneys furnace and water heater exhausts or other sources of contamination or carbon monoxide NEVER locate the fresh air inlet inside a structure Installing Return Air RA Ducts All the stale air returns are connected by ducts to the unit Generally empty stud cavities are used for returns as is often done with cold air returns for the furnace using standard duct boots to connect to six inch pipe at ...

Page 8: ...he HVAC AHU 24V AC dry contact relay to the terminal block so that when the ERV is operating the HVAC AHU blower operates to help distribute the fresh air through the existing ductwork if needed The unit has an optional terminal block for a MANUAL OVERRIDE SWITCH MOS connection Connect an ON OFF switch to the terminal block to manually switch the unit to high speed When the switch is off the unit ...

Reviews: