Assembly Instructions

5

.

 

Install Round Ductwork

a) Connect the round ductwork (not included) to the 

damper / duct connector, and run the ductwork to a 

roof or wall cap (not included)

b) Using tape (not included), secure all the ductwork 

connections so that they are air tight

c) Insulated flexible duct is recommended for the 

quietest possible installation. If rigid duct is used, a 

short (1-3ft) section of insulated flexible duct will 

ensure quiet operation

a) Install duct from the inside of the housing.

Fix the duct by the tab

b) Fix the blower assembly to the housing by 3 screws 

4

.

 

Install Duct and Blower Assembly

The ducting from this fan to the outside of building has a

strong effect on the air flow, noise and energy use of the fan.

Use the shortest, straightest duct routing possible for best 

performance, and avoid installing the fan with smaller ducts 

than recommended. Insulation around the ducts can reduce 

energy loss and inhibit mold growth. Fans installed with

existing ducts may not achieve their rated airflow.

Retrofit Installation

a) Mount with additional mounting holes:

The interior of the fan housing contains additional mounting 

holes in case exterior mounting is not possible. Screw or nail 

the fan housing directly to the framing or joists. Remove the 

blower assembly as directed in the service parts section of 

this manual's very last page to gain access to the additional 

mounting holes

b) Mount with hole of the flange:

Use screws (included) to screw fans to the ceiling through 

the holes of the housing

1. Remove wire panel and blower assembly before installation
2. Fold mounting hears flat against housing
3. Enlarge ceiling opening to 9-1/2" by 9-1/2", leave ductwork 

and wiring in place

4. Connect wiring according to the wiring diagram on the next 

page of this instruction manual. Re-install wire panel

5. Mounting fan

6.

Connect Duct:
Pull existing ducting through housing discharge opening and 
tape ducting to duct connector. Push connector / ducting 
back through opening, fix the duct by the tab

7. Install the blower assembly

Summary of Contents for ODC-1008

Page 1: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code...

Page 2: ...mounting flange 2 Mount with Mounting Holes and Hanger Bar a Slide one hanger bar into the channel on the housing and adjust as needed to fit between framing b Hold housing in place so that the housing contact the bottom of the joist Screw housing to joist through the hole of the housing c Screw the hanger bar onto the other side of joist through the hole d Screw hanger bar to housing with screw e...

Page 3: ...ce and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated airflow Retrofit Installation a Mount with additional mounting holes The interior of the fan housing contains additional mounting holes in case exterior mounting is not possible Screw or nail th...

Page 4: ...he wires as shown Install Grille Install ceiling material to complete the ceiling construction Then cut around the fan housing To attach the grille assembly to the fan housing pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots Push the grille assembly towards the ceiling to secure Service Parts Blow...

Reviews: