1.1 Safety Instruction  

Caution ! 

 

The  UPS  contains  voltages  which  are  potentially  hazardous.  All  repairs  should  be  performed  by 
qualified service personnel. 

 

The  UPS  has its own internal  energy  source (battery). The  output receptacles  may be  live  even  when 
the UPS is not connected to an AC supply. 

For safe and continuous operation of the UPS depend partially on the care taken by user. Please observe the 
following precautions. 

 

Do not disassemble the UPS. 

 

Do not attempt to power the UPS from any receptacle except a 2-pole 3-wire grounding receptacle. 

 

Do not place the UPS near water or in environment of excessive humidity. 

 

Do not allow liquid or any foreign object to get inside the UPS. 

 

Do not plug appliances, such as hair dryers, into the UPS receptacles. 

 

Do not place the UPS under direct sunshine or close to heat -emitting source. 

 

The power socket should be installed near the equipment and be easily accessible. To isolate from AC 
input, disconnect the plug in the power cord. 

 

The  printer  may  best  be  connected  directly  to  wall  receptacle  instead  of  UPS.  (laser  printer  can't  be 
connected to the UPS.) 

 

The battery will discharge naturally. If it is charged periodically, its life time will be prolonged. It will 
damage if long-term no use, which won't be covered in our warranty. 

 

1.2

 

System Description  

The UPS equipped with Boost-up and Buck-down features Accepts wide range input windows without using 
batteries.  It  is  your  best  choice  for  LAN  and  PC.  Built-in  RJ45  jacks  protect  your  modem/fax  line 
thoroughly. 
To enable user to start on the UPS without Utility Power, It is also equipped with "cold start function". 

 

2.

 

INSTALLATION AND OPERATION 

 

2.1.Unpacking and Inspection 

Examine  the  packing  carton  for  damage.  Notify  the  carrier  immediately  if  any  damage  occurs.  Retain  the 
packing for future use. 

 

2.2. Installation 

 

Connect the power cord to a verified grounded 3-wire receptacle. 

 

Charge the batteries for ten (10) hours before use. The UPS will recharge the batteries automatically 
whenever its power cord is plugged into a wall outlet. You may use the UPS immediately without 
recharging, but the backup time may be less than the rating. 

 

Connect the power cord of your computer equipment to the Backup Outlets of the UPS. Switch on the 
computer equipment. 

  Caution : Do not plug laser printers into the Backup Outlets because they may draw too much power. 

 

Switch  on  the  UPS  by  pressing  the  Main  Switch.  The  "Mains"  LED  will  light  on.  The  UPS  is  now 
considered  to  be  working  properl  If  overload  condition  occurs,  the  alarm  will  beep  continuously,  it 
means  you  have  connected  too  many  devices.  Please  proceed  to  unplug  the  least  critical  equipment 
from Backup Outlets. 

 

To test backup function, you may disconnect the power cord of the UPS. The "Mains" LED of the UPS 
will Light intermittently and the alarm will beep every 4 seconds. 

 

2.3. Storage Instruction 

For  extended  storage in moderate  climates, the batteries  should be  charged for 12 hours  every 3 months by 
plugging the power cord into the wall receptacle. Repeat it every 2 months in high temperature locations. 
 

3. OVERVIEW 

 

 

1. Sockets protected from grid failures and power surges. 
2. Overload/fault indicator. 
3. Battery mode indicator. 
4. Normal mode. 
5. On/off button (press at least 4 seconds). 
6. Sockets protected from power surges. 
7. Circuit breaker: protection from overloads. 
8. RJ11/RJ45 connectors: protects a tel./network line from power surges (available in 750/900 SP). 
9. USB connector: computer communication (available in 750/900 SP). 
10. Power cord (input). 

 

4. TROUBLESHOOTING 

 

The  Troubleshooting  chart  covers  most  of  the  difficulties  that  you  may  encounter  under  normal  working 
condition. Should the UPS fails to operate properly, please proceed the followings before calling for service. 

 

Is the UPS plugged into an incorrect wall receptacle? 

 

If AC input voltage out of windows? 

When calling for service, please offer  the following 
information 

 

Model No. and Serial No. 

 

Date of problem occur o Full description of the problem  occur, 

 

Including condition happened, environment installed, devices connected to the UPS, etc.. 

 

5. VISUAL & AUDIBLE ALARMS 

 

Normal mode without any load connected: diode no 4 is slowly flashing. 
Normal mode with load connected: diode no 4 is quickly flashing. 
Battery mode: 1 beep / 3 sec. Diode no 3 is slowly flashing. 
Low battery: 1 beep / sec. Diode no 3 is quickly flashing. 
Exhausted battery: Continuously beep (5 sec.) 

 
6. BATTERY REPLACEMENT 

1. Unplug the power cord from the socket. 
2. Unscrew two screws from  battery cover, slip out the cover. 
3. Take off and unplug the battery. 
4. Replace to battery this same type and connect properly (red to red). 
5. Put in the battery, close the cover and screw in the screws.

 