background image

18 

 

Long Term Maintenance and Inspection

 

 

See Figure 14 (3) Illustrations 

 

1.

 

Wiper Blade 

 Check for wear or damage every 6 months. Best to replace blade 

every 6 months if machine is used daily, replacement part #100413  

 

2.

 

High Pressure Hoses 

 Check for damage, wear or cracking every 6 months, see 

figure. 

a.

 

100288, HP Outlet Hose 1 

b.

 

100172, HP Outlet Hose 2 

c.

 

100378, 15 Degree nozzle HP Hose Assy 

d.

 

100358, Fine Detail Wand Assy 
 

3.

 

Low Pressure Hoses 

 Check for damage, wear or cracking every 6 months. 

 

a.

 

100247, Pump Inlet Hose 1 

b.

 

100289, Pump Inlet Hose 2 

c.

 

100285, Drain Hose Assy. 
 

4.

 

Gloves 

 Replace gloves every 6 months, replacement part #100407. 

 

5.

 

Pick-up Tube and Inlet Filter 

 Inspect every 6 months and replace if damaged, 

replacement part #100414. 

 

6.

 

Wands 

 Inspect every 6 months, or if Wands leak or Spray Patterns change. 

 

a.

 

100358, FINE Jet Wand and Hose Feed 

b.

 

100378, COARSE Jet Wand and Hose Feed 

 

 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SCA Waterjet

Page 1: ......

Page 2: ...This page intentionally left blank ...

Page 3: ...rjet 11 Mobile Setup 11 Stationary Setup 14 Operation 14 System Priming 14 Operator Position 15 Model Cleaning 16 Daily Maintenance and Inspection 17 Long Term Maintenance and Inspection 18 Glove Replacement Procedure 19 Troubleshooting 21 Specifications 23 Customer Support 24 Contact ORYX Support 24 Replacement and accessory parts 24 Supplemental Information 25 SCA Waterjet Cleaning System Limite...

Page 4: ...oor open Use the power supply voltage as noted in the Specifications section of this manual Avoid overloading the electrical outlet with multiple devices Use only the power cord supplied by the manufacturer Replace a damaged power cord with one approved by the manufacturer Ensure the system is well grounded Plugging the SCA Waterjet into a Ground Fault Interrupt GFI or similar protected outlet is ...

Page 5: ...alimentation endommagé par un autre approuvé par le fabricant Assurez vous que le système est correctement mis à la terre Il est recommandé de brancher le SCA Waterjet sur un interrupteur de fuite à la terre GFI ou une prise protégée similaire Éteignez et débranchez toujours le SCA Waterjet de la prise de courant lorsqu il est nettoyé déplacé ou réparé N utilisez pas le SCA Waterjet à d autres fin...

Page 6: ... for fine detail and delicate support removal High and low cleaning power settings High visibility work area environment through viewing window with efficient LED lighting and internal mount wiper blade assembly automatic operation Large processing environment to accommodate model sizes up to 19 5 x 15 5 x 9 The SCA Waterjet can be operated while standing or seated How It Works The interior work a...

Page 7: ...itional system components for the Stationary direct mode hook up The items shown in the figure below are shipped standard with the SCA Waterjet Figure 1 SCA Waterjet System Contents 1 SCA Waterjet 2 Cabinet Door and mounting hardware 3 Holding Tank 4 Foot Switch 5 Coarse Screen 6 Fine Screen 7 User Manual 8 Spare Gloves Not Shown ...

Page 8: ...ions Figure 3 Foot Switch Foot Switch opens the inlet shut off valve and activates the pump and wiper Never engage the Foot Switch without being properly positioned to operate the SCA Waterjet and having a firm grasp FIRST of the selected jet wand Ne jamais engager la pédale de commande sans être correctement positionné pour faire fonctionner le SCA Waterjet et avoir une prise ferme PREMIER de la ...

Page 9: ...ctivated Center OFF Position Neither jet wand is activated valve is closed and Pump will not run Left Fine jet wand is activated Figure 5 Coarse Jet Wand Hose Hanger Hose Hanger keeps Hose clear of Side Access Door opening when loading and unloading models into and from the work interior ...

Page 10: ...e and retract the lower latch plunger Lower door to fully closed position and release lower latch plunger Failure to grasp door handle and lower door by hand could result in operator injury or damage to door Also Only release the plunger after door has been lowered approximately one inch Friction from plunger will prevent door from slamming shut if accidently released Le fait de ne pas saisir la p...

Page 11: ... America 120VAC 60Hz 15A Europe 230VAC 50Hz 8A The electrical outlet must be located within 6 ft 2 m of the SCA Waterjet Do not use an extension cord or power strip with the system Mobile Setup Uncrate and remove all packing material Install Door See Figure 7 Install Fine Filter Screen and Coarse Filter Screen See Figure 8 Position Waterjet at final installation location and lock front Casters See...

Page 12: ...12 Figure 7 Install the Cabinet Door hardware included Figure 8 Install the Fine and Coarse Filter Screens interior work area Figure 9 Lock Front Casters after locating the SCA Watejet ...

Page 13: ...13 Figure 10 Level Cabinet side to side and angle front to back with Adjusting Screws 2 Figure 11 Holding Tank Drain Tube and Pick up Tube with Inlet Filter 0 5 Adjusting Screws Adjusting Screws ...

Page 14: ...démarrage initial et lorsque l eau du réservoir de stockage est remplacée 1 Verify holding tank is FULL mobile or facility inlet supply is ON stationary 2 Power on the unit Position the wand selector valve to the right Coarse Wand and set the pump switch to High 3 Be sure filter screens are in place and the cabinet access door is fully closed and then place hands in gloves and position them inside...

Page 15: ...endommager la pompe Ne modifiez jamais la puissance de nettoyage de la pompe lorsque la pompe est en marche Ne jamais basculer entre les baguettes lorsque la pompe est en marche Pour les modèles délicats mettez la pompe sur Faible pour un nettoyage à faible puissance et faites attention de ne pas endommager le modèle Operator Position The SCA Waterjet cleaning system can be operated from the stand...

Page 16: ...d with 0 Spray Use for close detail support removal from blind holes slots delicate and hard to reach features Figure 13 COARSE and FINE Spray Jet Wands Direct at model 6 to 8 inches away from it Cleaning Power Overview High Use the High Power setting for rigid and thick walled models Low Use the Low Power setting for delicate and thin walled models Cleaning process Power on the SCA Waterjet and s...

Page 17: ...When not in use leave the cabinet door open to allow the cabinet to dry out This will help reduce or eliminate mildew and or mold forming inside the work area 5 Maintenance Even though SCA Waterjet cleaning system is designed for low maintenance daily and long term inspections and maintenance are required Daily Maintenance and Inspection 1 CAUTION Inspect Gloves for wear or damage Replace if there...

Page 18: ...Hose 2 c 100378 15 Degree nozzle HP Hose Assy d 100358 Fine Detail Wand Assy 3 Low Pressure Hoses Check for damage wear or cracking every 6 months a 100247 Pump Inlet Hose 1 b 100289 Pump Inlet Hose 2 c 100285 Drain Hose Assy 4 Gloves Replace gloves every 6 months replacement part 100407 5 Pick up Tube and Inlet Filter Inspect every 6 months and replace if damaged replacement part 100414 6 Wands I...

Page 19: ...m Glove Inner Collar 3 Position new Gloves with thumbs up insert through arm holes a and fold edge of arm sleeve over and around Inner Glove Collar b 4 Reinstall Glove Outer Collar over fitted Glove CAUTION Tighten screws by hand to avoid overtightening them ATTENTION Serrez les vis à la main pour éviter de trop les serrer 100288 100172 100172 100247 100289 100285 100378 100358 ...

Page 20: ...20 Figure 15 Glove Removal and Replacement Procedure ...

Page 21: ...lace the breaker or fuse as required Power indicator has failed If the interior lights are on and the power switch is ON the power indicator has probably failed Contact technical support Pump will not start Power is not on Check the power switch indicator on the control panel Ifnot Lit see Power switch indicator is not lit Wand selector valve in off position The pump will only run when the wand se...

Page 22: ... for a replacement Note do not operate SCA Waterjet without the proper inlet filter Pump damage may result If dirty clean filter before reinstalling Nozzle on the wand is clogged Contact technical support Inlet supply lines are damaged or kinked Contact technical support Pump has failed Contact technical support Inlet shut off valve has failed Contact technical support Water leaks Hose or fitting ...

Page 23: ...r requirements A grounded electrical outlet North America 110VAC 20A 60Hz single phase Europe 220VAC 16A 50Hz within 2 m 6 ft of the SCA Waterjet Environmental Operation Specifications Operating temperature 5 C 40 C 41 F 104 F Operating relative humidity 0 80 RH Operating altitude 0 M 0 ft 2000 M 6561 ft Max pump operation Mobile On 30 minutes Off 30 minutes Maximum pump pressure 1700 psi Protecti...

Page 24: ...ple If the unit is covered by an extended warranty contact the Authorized Reseller from whom the unit was purchased Otherwise to receive technical support www oryxadditive com support proceed to the Request Technical Support page and fill out the support request form Send e mail to support oryxadditive com Please include full name company name phone number serial number Call 1 833 817 3533 and ask...

Page 25: ...roper installation improper maintenance or improper operation or application or if the machine was improperly repaired or serviced by the customer This warranty is void if the system is not installed by a certified distributor and the proper installation documentation provided by the manufacturer has not been submitted Liability whether based on warranty negligence or other cause arising out of an...

Page 26: ...26 Declaration of Conformity Visit www oryxadditive com to download Regulatory Compliance Certificates ...