The following are examples of recommended mixing procedures for WaterWorks and
EcoWorks in the SCA 3600.
If using WaterWorks Soluble Concentrate:
While wearing protective gloves, protective clothing, and eye/face shielding, add two
bottles (2.1 lbs, 950 grams each) of WaterWorks to the water filled bath. Exercise
caution when working with the cleaning solution. WaterWorks contains sodium
hydroxide
and always refer to the Manufacrer’s
SDS for PPE and handling requirements.
If using EcoWorks:
1.
Open the foil cleaning agent packet as shown. Each packet contains an A & B pouch.
2.
Empty all the contents of 13 (thirteen) foil cleaning agent packets into the water
filled tank. Avoid handling the contents of the cleaning agent bag.
Preheating and starting the cleaning cycle
Setting cycle time and temperature
Recommended Temperature Settings
Build
Material
Temperature Setting
WaterWorks
EcoWorks
ABS
70°C
Yes
Yes
PC
85°C
Yes
No
Nylon
50, 60 or 70°C**
Yes
Yes
**depending on part wall thickness and desired dimensional accuracy.
For MJ and PLA
parts select the ‘HEAT OFF’ option.