background image

WARRANTY REGISTRATION

Date _____________ Model No. or size ______________ Serial No. ____________
Customer Name______________________________________________________
Customer Address ____________________________________________________
City ________________State ______ Zip Code__________ Country ____________
E-mail* _____________________________________________________________
Date Purchased _______________ Where (dealership)_______________________
Dealer Address ______________________________________________________
City ________________State ______ Zip Code _________ Country ____________

o

 Yes. Please notify me about promotional offers, new products, and special  

 

    services from Osborne Industries. (*Please provide e-mail address above.)

Please print and mail

Osborne Stanfield

®

 Heat Pads are used to provide a warm lying area for small animals and are particularly important for piglets and other animals born without good body tempera

-

ture regulation or hair-coat protection.

INSTALLATION:

Osborne Stanfield

®

 Heat Pads must be anchored in a dry, well-drained location us

-

ing the corresponding Built-In frame. Information on the available Built-In frames can 

be obtained by contacting Osborne Customer Service. Drilling holes anywhere on the 

heat pad surface could damage the heater element.

Always install the heat pad so that the power cords are not accessible to the animals. 

A conduit such as the Osborne Cord Protector, plastic pipe, or electrical conduit shall 

be used. Damage to the cords caused by insufficient protection is not covered by war

-

ranty and may result in hazardous electric shock.

Stanfield

®

 Heat Pad Instructions & Warranty

WARNING

Large animals or careless handling can damage power supply cords and heat pads. Such damage may cause a life-threatening electric shock hazard and may start 

a fire if combustible material is present winthin a distance of 5 cm (0.05m). Do not permit access by adult animals to the power cords or heat pads. Installation and 

disconnection shall be in accordance with local wiring rules and electrical codes.

DO NOT COVER. RISK OF FIRE, FLAMMABLE MATERIALS. Do not carry heat pads by their power supply cords. Do not use heat pads 

in the presence of combustible materials. Always disconnect power while washing heat pads. The power supply cord cannot be replaced. 

If damage to the heat pad or cord is detected, remove the heat pad from service immediately and contact Osborne Industries, Inc.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that 

they do not play with the appliance.

The Built-In frames are attached around the outer edge of the heat pad and then the 

entire assembly is inserted into the flooring section properly designated for the Built-In 

heat pad assembly. The figure below shows a typical Built-In installation.

OPERATION:

Osborne Stanfield

®

 Heat Pads do not use an internal thermostat. At full rated input 

voltage, they operate at a fixed temperature rise above the ambient air temperature 

which is often adequate if room temperature is 65-70 °F (18-21 °C) for piglets and 

similar small animals. For complete year-round control of heat pad temperature and 

best efficiency, control power and temperature with an Osborne Heat Pad Control.

INSTALLATION:

If non-use of the pad is observed, check the following:

A.  Is electrical power applied to the pad? Placing the palm of the hand on the 

pad for several seconds results in a “warm” feeling if power is applied.

B.  If the heat pad is warm, but animals are not using it, check for drafts in the 

area compared to the area where the animals do lay. Change ventilation to 

reduce the draft to acceptable levels.

C.  If the animals seem restless, lie next to heat pad, but not on it, or use it only 

intermittently, it may be too warm. Reduce air temperature or add controls or 

reduce setting of controls until animals rest comfortably again.

Always keep the heat pad clean and dry for longest life and best performance.

Divider Panel

Heat Pad with 

Built-In Frame

Built-In Floor

Section

WARNING

Never take chances. Always protect the heat pad from adult animals and 

anchor it so that it cannot be moved. Protect power cords from both adult and 

small animals.

Osborne Stanfield Heat Pads are tested and certified to meet 

or exceed UL, CSA, CE, IEC, and PSE standards for safe con

-

struction and operation.

Cut Here 

ヒートパッドは安全に高圧洗浄、こする、削る、水に浸す、消毒することが出
来ます。洗浄のあとは乾燥させてください。乾燥した状態を維持してくださ
い。スタンフィールドヒートパッドは耐水性ですが、継続した水や尿への暴露
は故障を早めます。

警告

免許を持った電気技師が漏電遮断機のついた電源にのみヒートパッドを接続
してください。漏電遮断機を使用しない場合、豚や使用者が電気ショックを

受ける可能性があります。

保証声明

オズボーンはヒートパッド及びコントローラーに関して通常の用途で使用
している限り、1年間は商品、品質を保証します。電源コードやセンサー
の延長は保証外となります。弊社の試験で欠陥が明らかになったヒートパ
ッドやコントローラーは無料で修理、若しくは交換いたします。欠陥品は
綺麗な状態で購入元か、オズボーンの代理店に返品してください。もし保
証登録カードが購入時に返送されない場合、返品した商品は売上伝票原本
が示す販売日時、シリアルナンバーの複製かもしれません。所有者の名
前、住所を商品に記載してください。シリアルナンバーや工場からの出荷
日は商品の登録が無い、若しくは購入の証拠がない場合に保証期間を決定
するために用いられます。オズボーンは改造や誤用、乱用による欠損に対
して一切の責を負いません。この保証は修理、交換、間接的な損害、特別
な欠損について行います。

警告

洗浄、高圧洗浄する前に電源を抜いてください。気づかない損傷によって電

気ショックが引き起こされます。

ヒートパッドは閉鎖された場所以外では室温を上昇させません。表面も極

端に熱くはなりません。ヒートパッドは断熱で豚の体温低下を防ぎます。これ
により特に、寝ている間に体温を一定に保つことが出来ます。電源が供給され
てすぐは床への熱損失が少しありますが、床が暖めると熱損失は減少します。

警告

寝わらや肥料、がれきでヒートパッドを覆わないでください。可燃物でヒー
トパッドを覆わないでください。何かで覆ってしまうと加熱しすぎたり火災

の原因となったり、商品の寿命を縮めてしまいます。清潔してに乾燥させ

てください。

洗浄に関する説明

100V /100-110V

ヒートパッド

電源コードプロテクター

FH-00F150 OR FH-00F152

配電盤

防滴用スイッチカバー

ひとまとめにしたアース線

ひとまとめにした共通線

電源スイッチ

熱線

共通

アース線

1800mm

電源コード

取付け、取外しは地域の配線ルール、電気工事

規定に従い、資格のある専門業者が認証を受け

た部品を用いて行ってください。

ヒートパッド設置に必要なサイズ

型番

サイズ

RJS1B3

31 x 92

RJS1B4

31 x 122

RJS1B5

31 x 153

RJS2B3

61 x 92

RJS2B4

61 x 122

RJS2B5

61 x 153

RJS120

64 x 99

RJS203

61 x 92

RJS303

92 x 92

RJS304

92 x 122

RJS1824

46 x 61

電気に関する条件:

通常の基準である100V又は100-110Vが供給された配電盤に接続した電源コ

ードから電気を供給してください。一般的な接続方法は上記の通りです。

Osborne Industries, Inc. · Box 388 · Osborne, KS 67473 · USA

Printed in the USA · 

RLX-0556_B

Osborne Stanfield Heat Pads are tested and certified to meet 

or exceed UL, CSA, CE, IEC, and PSE standards for safe con

-

struction and operation.

BOX 388
Osborne, KS 67473
USA

スタンプ

____________________________
____________________________
____________________________
____________________________

Reviews: