Page 33
Installation and Operation Manual - 1700
ENGLISH
8.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
14
½
" (368 mm)
14
½
" (368 mm)
A
9
½
" (241 mm)
9
½
" (241 mm)
B
12" (305 mm)
12" (305 mm)
B
12" (305 mm)
12" (305 mm)
C
13" (330 mm)
13" (330 mm)
C
13" (330 mm)
13" (330 mm)
L
78" (1981 mm)
78" (1981 mm)
L
78" (1981 mm)
78" (1981 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
2
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
2
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
18" (457 mm)
D
13" (330 mm)
13" (330 mm)
E
21" (533 mm)
21" (533 mm)
E
21" (533 mm)
21" (533 mm)
F
21 ¾" (552 mm)
21 ¾" (552 mm)
F
21 ¾" (552 mm)
21 ¾" (552 mm)
8.1.3 With Heat Shield AC02710 and Lowered Ceiling
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat
shield certified with the single wall pipe connector to be used as close as 6" from combustible
materials must be used. Only in this case, the same clearances as a certified double wall pipe
connector can be used.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
2
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
2 ½" (64 mm)
2 ½" (64 mm)
D
6" (152 mm)
6" (152 mm)
B
2 ½" (64 mm)
2 ½" (64 mm)
E
11 ½" (292 mm)
11 ½" (292 mm)
C
2 ½" (64 mm)
2 ½" (64 mm)
F
11 ¼" (286 mm)
11 ¼" (286 mm)
L
78" (1981 mm)
78" (1981 mm)
2
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.