Installation and operating manual

               

-30

230V filter control unit with solar control

Item No.: 310.000.0530

Function

The 

 PC-30 filter control unit allows time-dependent switching on and off of a 230 V 

alternating   current   filter   pump   in   accordance   with   a   freely-programmable   switching 
program.
heater of the swimming pool is controlled by the electronic temperature regulation system 
while the filter pump is running. The heater is automatically switched off by the internal 
interlock during  filter pauses. The  required  swimming pool  water  temperature  can be 
selected on the front panel, or the heater can be switched off. A floating contact (terminals 
22  +  23)  and  a  230  V  output   (terminals  U2  and  N)  are  available  for connecting  the 
heating. Terminals for a

  solar actuating drive are available for operation with solar 

absorbers through which the swimming pool water flows directly.
The integrated frost protection function makes the swimming pool winter break easier to 
deal with. 
Terminals   for   electronic   level   regulation   NR-12-TRS-2   (Art.   No.   3030075020)   enable 
convenient automatic regulation of the swimming pool water level. The filter pump is also 
additionally   protected  against   damage  which   could   be   caused   by   filter   unit   operation 
without water.
Bar valves for backflushing and rinsing can be connected directly to the PC-30 so that 
separate backflushing control units are not necessary. If a 6-way valve is to be used for  
backflushing, additional terminals for an

  EUROTRONIK-10 enable extension of the 

filter control unit to an automatic filter and backflushing control unit for 6-way valves.
Extra terminals enable the connection of additional devices such as a dosing system. 
Terminals 20 + 21 are floating, and can therefore be used individually. The relay contact 
between terminals 20 and 21 remains closed during the filter periods, the relay contact is 
opened outside these periods. This contact can be loaded with a voltage of maximum 230 
V and a current of maximum 4 A.
Operation of filter pump and heater is displayed by indicator lamps in the front panel,  
which means that checks can be made at any time.

Summary of Contents for 310.000.0530

Page 1: ...easier to deal with Terminals for electronic level regulation NR 12 TRS 2 Art No 3030075020 enable convenient automatic regulation of the swimming pool water level The filter pump is also additionally...

Page 2: ...8 Programming backflushing 9 Info key 9 Balancing the temperature controller 9 Fuses 10 Service terminal 10 Filter unit operating mode 10 Heater operating mode 11 Water temperature 11 Solar temperatur...

Page 3: ...ce must be powered via a multi pole main switch with a contact opening width of at least 3mm and a residual current circuit breaker with IFN 30mA The device must be isolated before opening the housing...

Page 4: ...on reservoir 11 12 13 14 11 1213 14 U3 N R cksp lventil 230V max 400W EUROTRONIK 10 2 3 4 5 2 3 4 5 Backflushing controller U4 N Klarsp lventil 230V max 400W Bar valves 230V can be connected for backf...

Page 5: ...into the piping system The sensor polarity is as required A solar temperature sensor Art No 3100000030 can additionally be connected to terminals 32 and 33 optional The temperature sensor is supplied...

Page 6: ...EUROTRONIK 10 or the NR 12 TRS 2 level regulation system Back flush The filter pump is switched on because backflushing is taking place using the bar valve connected Rinse The filter pump is switched...

Page 7: ...shows 24 5 Water C 2 Use the and keys to set the required temperature between 0 C and 40 C 3 Press the key again to save the required temperature If no key is pressed for more than 10 seconds during...

Page 8: ...on time minutes 4 Press the key again the hours in the switch on time blink 5 You can now use the and keys to set the required switch on time hours 6 Press the key again the minutes in the switch off...

Page 9: ...sf PC30 ver 1 00 After this you can press the INFO key again to call up the following information 1 Time 2 Solar temperature 3 Water temperature 4 Filter pump operating status 5 Solar heater operating...

Page 10: ...mains Once the control system has been switched on the service terminal display shows the first 4 lines of the diagnosis text e g Filter operation Temp reached Water 23 0 Solar 38 4 Filter unit operat...

Page 11: ...perature is below the set temperature and the collector is warmer than the swimming pool water Frost hazard The heater is switched on in frost protection operating mode Water temperature The current w...

Page 12: ...e saved automatically A temperature difference of 3 is set at the works Solar additional temperature This line displays by how much the swimming pool set temperature may be exceeded during solar heati...

Page 13: ...s 3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate The adjusted value will be saved automatically The time set here only influences the temper...

Page 14: ...is line displays the total operating hours for the additional heater Solar operating time This line displays the total operating hours for the solar heater Backflushing counter internal This line disp...

Page 15: ...mp and the additional heater are switched on automatically If the priority circuit is displayed in the top line of the service terminal it can be switched on or off 1 Once the key has been pressed the...

Page 16: ...p on and the key to switch it off 3 If you press the key again the normal diagnosis display appears and the filter unit continues to operate Solar operation When the solar heater operating status is d...

Page 17: ...display appears and the filter unit continues to operate Backflushing valve When the backflushing valve operating status is displayed in the top line of the service terminal it can be switched manual...

Page 18: ...e switched over 1 If you press the key the following is displayed Language selection German English 2 Now use the and keys to change the selected language 3 If the key is pressed once again the normal...

Reviews: