PC-30 Filter control unit operating manual Page: 3
Specifications
Dimensions:
220mm x 219mm x 100mm
Operational voltage:
230V/50Hz
Control system power consumption:
ca. 10VA
Switching capacity:
Pump:
max. 1.1 kW (AC3)
Heater:
max. 230V/4A
Dosing system:
max. 230V/4A
Protection class:
IP 40
Installation
The controller must be mounted protected against moisture in accordance with its
protection class. The device must be powered via a multi-pole main switch with a contact
opening width of at least 3mm and a residual current circuit breaker with I
FN
≤
30mA .
The device must be isolated before opening the housing.
Electrical power supply
Electrical power supply connections, in addition to alignment and service work,
may only be carried out by approved electricians. The attached circuit diagrams
and all applicable safety regulations must be observed
.
Mains connection and filter pump connection
Pool-Control-30
1
M
U1
L
N
230V max. 8A
Filter pump
max. B16A
Back up fuse
FI-switch
Power
1/N/
230V 50Hz
25A/0,03A
N