background image

Installation and Operating Instructions 

 

 

 

 

 

PC-230-smart 

with Internet facility

 

Part no. 310.000.1230 

 

Technical data 

Dimensions: 

220mm x 285mm x 85mm 

Operating voltage: 

230V 50Hz 

Power consumption of control unit: 

1,5VA approx. 

Switching capacity: 

Pump: 

Heating: 

max. 1,0 kW (AC3) 

max.0,4kW (AC3) 

Degree of protection: 

 

IP 40 

Air humidity: 

 

0-95% non condensing 

Ambient temperature: 

 

0-40°C 

Summary of Contents for 310.000.1230

Page 1: ...310 000 1230 Technical data Dimensions 220mm x 285mm x 85mm Operating voltage 230V 50Hz Power consumption of control unit 1 5VA approx Switching capacity Pump Heating max 1 0 kW AC3 max 0 4kW AC3 Deg...

Page 2: ...peration 6 Touchscreen 6 Switching the PC 230 smart on and off 6 Changing the operating mode of the filtration pump 6 Changing the heating operating mode 7 Setting the required temperature 7 Setting t...

Page 3: ...tout or flow sensor for additional protection against the heater overheating The touchscreen can be used to select the required pool temperature or to switch off the heating d Adjusting the system tim...

Page 4: ...nnecting a filter pump with speed control We have other controls in our range for this type of pump The factory inserted link between the two terminals labelled Th must be removed when connecting a sa...

Page 5: ...ease see Calibrating the temperature on page 8 The following table can be used for checking the temperature sensor Resistance values of the temperature sensor Temperature Resistance 20 C 5800 Ohm 25 C...

Page 6: ...utton to switch off the unit Changing the operating mode of the filtration pump The Filtration pump button can be used to select the operating mode ON AUTO OFF ON runs continuously AUTO runs under tim...

Page 7: ...decreases the required temperature The displayed value is saved automatically Press the button to return to the home screen Setting the time The clock time can be set by pressing the Time button Press...

Page 8: ...the language Press the Language button Press the individual button to select the required language The symbol identifies which language is currently selected Press the button to return to the Main me...

Page 9: ...ows to adjust the time difference The displayed value is saved automatically Press the button to return to the Time settings menu Change the network settings Press the Network settings button In the N...

Page 10: ...tructions PC 230 smart Page 10 10 PC 230 smart combined with NR 12 TRS 2 and EUROTRONIK 10 Subject to changes April 21 Water level controller for overflow pools with spillway Backwash controller EUROT...

Reviews: