Operating instructions EUROTRONIK-20 Page: 6
Operating elements
LCD display
Controller ON/OFF
Set time
Backwash (manual)
Program timer
Close valve
Empty swimming pool
Change values
(Backwash and clear rinsing times)
Manual control of pump
Program timer
(Filtration times)
LCD display
Thu 8:46
Filter
Normal operating display during filter time showing the current time and valve position.
Thu 9:18
Pause
Normal operating display without filtration showing the current time.
Thu 6:32
Manually
Normal operating display with manually activated filter pump showing the current time.
Lift
Backwash
The backwashing cycle has been started. The valve disk is first lifted.
Rotate
Backwash
The valve disk is turned into the position
Backwash
.
Lower
Backwash
The valve disk is lowered into the position
Backwash
.
4:39
Backwash
The backwashing cycle is running. The remaining backwash time is displayed (in
min.:sec.).
Lift
Cl.Rinse
After backwashing the valve disk is lifted again.
Rotate
Cl.Rinse
The valve disk is turned into the position
Clear Rinse
.
Lower
Cl.Rinse
The valve disk is lowered into the position
Clear Rinse
.
0:10
Cl.Rinse
The clear rinsing cycle is running. The remaining rinsing time is displayed (in
min.:sec.).
Lift
Filter
The valve disk is lifted to be turned into the position
Filter
.
Rotate
Filter
The valve disk is turned back into the position
Filter
.
Lower
Filter
The valve disk is lowered into the position
Filter
.
Lift
Empty
The valve disk is lifted to be turned into the position
Empty
.
Summary of Contents for 3104811211