SECTION 3 - CHASSIS & SCISSOR ARMS
3-28
31215074
3.8
MDI (MULTIFUNCTION DIGITAL INDICATOR)
AND BRAKE RELEASE
Installation:
NOTICE
ENSURE EMS BUTTONS ON THE CONTROL STATIONS ARE
PUSHED IN TO THE OFF POSITION BEFORE CONNECTING AND
MOUNTING THE MDI AND BRAKE RELEASE BRACKET.
1. Open the Battery Cover on the right side of the
machine (ground control station side). Lifting up
on the battery tray and pulling out will allow for
maximum extension.
2. Locate the Diagnostic Port (1) and Brake Release
Plugs (2).
3. Apply di-electric grease to the two Brake Release
Plugs. Connect the Brake Release Plugs to the
Brake Release Button on the backside of the
mounting bracket.
NOTE:
The brake release plugs have no polarity, therefore,
can be connected to either post on the button.
4. Connect the MDI harness to the Diagnostic Port.
MDI and Brake Release Bracket
1. Diagnostic Port
2. Brake Release Plugs
1. MDI Connected
2. Brake Release Connected
Go
to
Discount-Equipment.com
to
order
your
parts