SECTION 6 - ACCESSORIES
6-8
31215036
• Do not weld to platform.
• Do not ground through the platform.
• Do not use a high frequency arc starter with TIG welder.
Preparation and Inspection
Connect ground clamp to metal being welded, make sure there is
a good ground connection and observe proper polarity, begin
welding.
Operation
Start engine turn on generator then turn on welder.
Wear proper welding apparel. Set welder to proper amperage
and voltage settings for thickness and type of metal being
welded. Begin welding.
Refer to Miller Welder Operators Manual.
Generator will not start under an electrical load.
6.3
SKYGLAZIER™
The SkyGlazier™ allows glaziers to efficiently position panels. The
glazier package consists of a tray that extends from the bottom of
the platform. The panel rests on the tray and against top-rail of
the platform, which is padded to prevent damage to the panel.
The SkyGlazier™ includes a strap to secure the panel to the plat
-
form rail.
Safety Precautions
ENSURE LOAD IS SECURED WITH LOAD STRAP.
DO NOT OVERLOAD TRAY OR PLATFORM. TOTAL MACHINE CAPACITY IS REDUCED
WHEN TRAY IS INSTALLED.
WITH THE SKYGLAZIER INSTALLED, THE ORIGINAL PLATFORM CAPACITY RATINGS
ARE REDUCED AS SHOWN IN TABLE 6-4, SPECIFICATIONS FOR SKYGLAZIER™. DO NOT
EXCEED THE NEW PLATFORM CAPACITY RATING. REFER TO CAPACITY DECAL LOCATED
ON TRAY.