Hydraulic Oil Check Procedure
To ensure proper operation of the machine, the hydraulic oil must be
checked daily.
Check the hydraulic oil level only when the machine is in the stowed
position. Ensure the hydraulic oil has warmed to operating tempera
-
ture before checking the reservoir.
1.
Open the hydraulic compartment door and locate the
hydraulic reservoir (
1
).
2.
Locate the lines indicating the maximum and minimum lev
-
els of hydraulic oil (
2
and
3
) in the reservoir. Ensure the level
of oil is between the two lines.
3.
If the level of oil in the reservoir is below the minimum level
(
3
), more oil is needed. Wipe all dirt and debris from the
filler/filter cap (
4
) and surrounding area.
4.
Remove filler cap and add proper grade of oil. Fill until oil
level is close to the
maximum level (
2
). Do not overfill.
NOTE:
Take precautions so impurities (dirt, water, etc.) cannot enter the
hydraulic system while filler/filter cap is removed.
NOTE:
Recommended lubrication intervals are based on machine oper
-
ations under normal conditions. For machines used in multi-shift
operations and/or exposed to hostile environments or condi
-
tions, lubrication frequencies must be increased accordingly.
5()
5()
5()
0"%
Summary of Contents for JLG R2632
Page 6: ...REVISION LOG d 31215932 REVISION LOG Original Issue A September 1 2020...
Page 22: ...SECTION 1 SAFETY PRECAUTIONS 1 12 31215932 NOTES...
Page 32: ...SECTION 2 USER RESPONSIBILITIES MACHINE PREPARATION AND INSPECTION 2 10 31215932 NOTES...
Page 62: ...SECTION 4 EMERGENCY PROCEDURES 4 4 31215932 NOTES...
Page 93: ...SECTION 6 SPECIFICATIONS AND OPERATOR MAINTENANCE 31215932 6 15 0...
Page 104: ...SECTION 6 SPECIFICATIONS AND OPERATOR MAINTENANCE 6 26 31215932 NOTES...
Page 106: ...SECTION 7 INSPECTION AND REPAIR LOG 7 2 31215932 DATE COMMENTS...
Page 107: ......