SECTION 5 – GENERAL SPECIFICATIONS AND MAINTENANCE
– JLG Lift –
5-51
2-3 Ground Controls
2242
FUNCTION LOCKED OUT -
MAST JOYSTICK NOT
CENTERED
The Mast Joystick was not centered at power-up
in platform mode.
• Release joystick and allow to center.
• Check if the joystick is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
2243
FUNCTION LOCKED OUT - JIB
JOYSTICK NOT CENTERED
The Jib Joystick was not centered at power-up in
platform mode.
• Release joystick and allow to center.
• Check if the joystick is not obstructed or jammed.
Refer problem to a qualified JLG mechanic.
2244
GATE LIMIT SWITCH - FAULTY
If equipped - A problem has been detected in this
function.
• Check if the Gate Limit Switches are damaged, obstructed or
jammed.
Refer problem to a qualified JLG mechanic.