Section 7- Lubrication and Maintenance
7
-
33
31211368
3. LSI indicator LEDs (
3
) will illuminate sequentially then repeat if check is successful. LSI
indicator LEDs will resume normal functionality when control buttons are released.
4. If check fails, a fault code will appear in the LCD display (
4
) and must be corrected
before continued use. Repeat system check or re-calibrate machine. See Service
Manual for LSI system calibration information.