Section 3- Controls and Indicators
3
-
42
31211368
a.
Screen Brightness:
Screen brightness allows the operator to adjust the screen
brightness (0 - 100% in 1% increment).
b.
Auto Brightness:
Auto brightness screen allows the operator to set auto
brightness to enable or disable mode.
c.
Auto Brightness Threshold:
Auto brightness threshold allows the operator to
adjust the auto brightness threshold value when auto brightness is enabled.
Based on ambient light level and auto brightness threshold, display will set to
auto brightness low level or screen brightness.
d.
Auto Brightness Timer:
Auto brightness timer allows the operator to adjust the
length of time to change to appropriate brightness when auto brightness is
enabled.
e.
Auto Brightness Low Level:
Auto brightness low level allows the operator to set
the preferred lowest brightness level (in %) when auto brightness is enabled.
Clock Format 24 Hours:
Clock format screen allows the operator to set the real-time
clock in 12 or 24 hour format.
Real-Time Clock (RTC):
Real-time clock screen allows the operator to set hours,
minutes, month, day and year by the use of navigation button.
Language:
Language allows the operator to view the current language. See Service
Manual to change current language.
Maintenance Icon Enable:
Maintenance icon enable screen allows the operator to
set the maintenance status to enable or disable mode on the home screen.
Revision#:
Revision# screen displays the revision numbers of all libraries (capacity
and maintenance chart) and application.