SECTION 3 - MACHINE CONTROLS AND INDICATORS
31215048
3-7
NOTE:
When the Platform/Ground Select Switch is in the
center position, power is shut off to the controls at
both operating consoles. Remove the key to pre
-
vent the controls from being actuated. The key is
removable in the platform position on CE specifi
-
cation machines. The key must be available to
ground personnel in the event of an emergency.
5.
Platform/Ground Select Switch
The three position, key operated switch sup
-
plies power to the platform control console
when positioned to Platform. With the switch
key turned to the Ground position only
ground controls are operable.
6.
Hourmeter
Registers the amount of time the
machine has been in use, with engine
running. By connecting into the oil
pressure circuit of the engine, only engine run hours are
recorded. The hourmeter registers up to 9,999.9 hours and
cannot be reset.
NOTE:
On machines with diesel engines, when Glow Plug Indicator is
lighted (Yellow), wait until light goes out before cranking engine.
7.
Power/Emergency Stop Switch
A two-position red mushroom shaped switch
supplies power to Platform/Ground Select
switch when pulled out (On). When pushed in
(Off), power is shut off to the Platform/Ground Select switch.
8.
Engine Start/Auxiliary Power Switch
To start the engine, the switch must be held Up
until the engine starts.
To use auxiliary power, the switch must be held
Down for duration of auxiliary pump use. Auxiliary
power can only be used if the engine is not running.
NOTE:
Auxiliary power only works if there is no engine oil pressure, and
is disabled if engine is running.
NOTE:
Functions will operate at a slower than normal rate because of
the lesser flow of hydraulic fluid delivered.
WHEN USING AUXILIARY POWER, DO NOT OPERATE MORE THAN ONE FUNCTION AT A
TIME. (SIMULTANEOUS OPERATION CAN OVERLOAD THE AUXILIARY PUMP.)
To
order
go
to
Discount-Equipment.com