SECTION 3 - CHASSIS & TURNTABLE
3121623
– JLG Lift –
3-29
Those instructions are valid for engines with no key
switch
.
Figure 3-55.
On engine right side access to the harness, and disconnect
the engine harness plug.
Figure 3-56.
On female connector jump the following wires:
•
Pin12 (12 Volt supply) battery positive terminal.
•
Pin 5 (Starter) for a moment utilize hook up this pin as
key starter.
Figure 3-57.
LED’s On when Pin 12 feed with 12 Volt.
To turn off the engine remove the supply voltage to Pin
12