POSSIBLE MALFUNCTIONS
FAILURE
WATER LEAKS
Filter housings
Connectors (threaded part)
Connectors (tube part)
O-ring dirty, misplaced or pinched
Needs teflon
Bicone wrong installed
Faucet
Connector not threaded enough
Pinched or wrong cutted tube
Adjunt the handle height
LOW PRODUCTION
When open the faucet,
the supply stops
immediatly, remaining
a slight continuous flow.
The tank is full
The tank valve is closed
Chopped accumulator membrane,
water flows through the air inlet valve.
Cambiar el acumulador.
Taked between 3 and 5 hours to have the tank full.
LOW PRODUCTION
The equipment rejects
water continuosly into
the drain
THE EQUIPMENT
IS NOT PRODUCING
CHANGE ON THE
WATER TASTE
POOR APPEARANCE
WATER
The tank is empty
Tank does not fill
The water tank inlet is closed
Too much air in the tank. Check the pressure between
0.3 Kg. and 0.5 Kg.
Dirty filters. Change
The inlet pressure is less than 3kg/cm². Install a pump
Change the membrane
Shutoff valve is dirty or the membrane is not working.
Change
Flushing valve opened
Tank is full enough
The tank is empty
Water has a milky appearance
after flowing from the faucet
Blocked filters
Blocked, broken or closed inlet valve
Blocked membrane
Change on the water mineralization due to saturation
or to filters or membrane blockage (change them)
Flow restrictor or drain blocked. Check
Possible water leak
Pressure is not enough.
Install a water pump.
The check elbow placed in the membrane housing does
not work. Change
if worn, replace faucet
Lack air in the tank. Replenish between 0.3 and 0.5 kg
ORIGIN
SOLUTION
Air bags accumulated in the pipes
or in the R.O. equipment
Shutoff valve in poor condition. Change
Membrane housing in poor condition. Change