9
RECOMMENDATION
-
If the maximum water pressure exceeds 6 bar in a 24-hour period, a reduction valve and expansion
vessel should be fitted.
-
For installation in a rooms which does not conform to the wetroom standard, a watertight
drip tray with overflow pipe > 18 mm. inside diameter should be fitted under the product, in
addition to an automatic stop cock with sensor. This will prevent possible material damage.
3.5.4 Fitting instructions
3.5.5 Fitting recommendation
!
CAUTION
!
The product should be placed in a room with a drain, in accordance with the wetroom
standard / latest TEK. Alternatively, fit an automatic stop valve with sensor and overflow
from safety valve to drain.
!
The product should be properly aligned vertically and horizontally, on a floor suitable for the
total weight of the product when in operation. See type plate.
!
The product must have a clearance for servicing of 40 cm in front of the junction box / 10 cm
over the top connection.