RECOMMENDATION
- The mains cable supplied should be used with fixed electric fittings.
- Mains cable for wall socket should be laid where it is not exposed to harmful contact.
-
For products with ≤ 3kW capacity, The unit must be permanently to 20amp DP Switch (
BS3455) with minimum 3mm separation and 2.5mm Flexible Cable HR to 85c (HOFR to BS
6141 Table 8), installation shall comply with current IEE Regulations. Immersion Heater rating
is 230v x 3kw. All internal wiring is factory mounted.
3.6.5 Installation instructions
3.6.6 Fitting recommendation
!
WARNING
!
The product should be filled with water before the power is switched on.
!
Fixed electric fittings should be used for installation in new homes or when changing an existing
electrical setup in accordance with regulations.
!
The mains cable should withstand 90°C. A strain reliever must be fitted.
!
CAUTION
!
The product must have a clearance for servicing of 40 cm in front and side.