3.5 Pipe installation
3.5.1 Incoming water pressure
The efficiency of the product depends on the in-
coming cold water pressure. The water pressure
should be min. 2 bar and max. 6 bar throughout
the day. Excessive water pressure can be adjusted
by installing a pressure reduction valve.
3.5.2 Fitting cold and hot water pipes (CW-HW),
safety valve and overflow pipe
A) Product placed in the desired position.
B) CW (1)/HW (2) pipes of suitable sizes fitted
to the connections and tightened.
• For larger pipe sizes, a reducer can
be used.
C) The safety valve supplied (3) must
be mounted on the incoming CW pipe.
D) Any overflow pipe (5) > 1/2" inside should be
run to the overflow on the safety valve (4);
• Connect to 1/2" outside thread. Ring clamp
connector may be used (not included)
• Clear, undamaged and frost-free with
a fall to the drain.
The product is designed to be permanently con-
nected to the mains water supply. Approved pipes
of the correct size should be used for installation.
The relevant standards and regulations must be
followed.
* Mounting band for wall mounting fitted as de-
scribed in section 3.3.3. Screws for wall mounting
tightened until the insulation material starts to de-
form.
The product should be hung on a wall surface de-
signed to withstand the weight of the product in
operation.
Component
Torque
Connection to CW/HW (ø15)
40 Nm (+/- 3)
Ring clamp connection to safety valve 40 Nm (+/- 3)
Screws for mounting band