13
5.2 Maintenance
5.1 Settings
5.1.1 Setting the mixer valve
The outgoing hot water temperature from the product
to the taps in the home can be adjusted with the knob
on the mixer valve. To adjust the temperature:
A) Turn the adjustable knob (1) all the way to ‘+’
B) Then turn the knob towards ‘-’ to the desired tem-
perature.
5.1.2 Adjusting the feet
The product is equipped with three factory-fitted feet,
adjustable from 0-40 mm. Screw the feet out a mini-
mum of 15 mm from the bottom of the product. Adjust
the feet individually until the product is standing firmly
vertically and horizontally.
5. USER GUIDE
Turns
Temperature
0
Approx. 70°C
1/4
Approx. 60°C
1/2
Approx. 50°C
3/4
Approx. 40°C
1
MAINTENANCE INSTRUCTIONS
!
Maintenance should be carried out by persons over 18 years of age, with suf-
ficient understanding
!
Annual inspection of safety valve:
- Open valve for 1 min. by turning the knob (3) approx. 90 degrees to the
open position.
- Visually check that the water is flowing freely to the drain.
- YES = OK. Close the valve by turning the knob (3) a further 90 degrees.
- NO = NOT OK. Disconnect power supply / shut off water supply. Contact
installer.
3