RECOMMENDATION
- Allow clearance to the floor. Screw the feet out a minimum of 15 mm from the bottom of
the product.
-
Overflow pipe from the safety valve to the drain (1) and mains cable for wall socket (2) should
be hidden under the channels in the bottom of the product.
-
If a non-return valve is fitted a reduction valve and expansion vessel should be fitted to stop
dripping from the safety valve.
-
If the maximum water pressure exceeds 6 bar in a 24-hour period, a reduction valve and
expansion vessel shall be fitted.
3.5.5 Fitting instructions
3.5.6 Installation recommendation
!
CAUTION
!
The product shall be placed in a room with a floor drain.
The manufacturer assumes no responsibility whatsoever if this provision is not followed.
!
The product shall be properly aligned vertically and horizontally, on a floor or wall suit-
able for the total weight of the product when in operation. See type plate.
!
The product shall have a clearance for servicing of 40 cm in front of the electric cover / 10 cm
over the highest point.
!
WARNING
!
The product shall be filled with water before the power is switched on.
!
The discharge pipe from any safety device shall be at least one pipe size larger than the
nominal outlet size of the safety device (< 9m length). The discharge pipe shall have
continuous fall to drain, be uninterruptable and frost-free at all times.