13
!
WARNING
Constant voltage present in the junction box.
Before any electrical work is done, the power
supply must be disconnected and secured
against activation while the work is in progress.
Turns
Temperature
0
Approx. 70°C
1/4
Approx. 60°C
1/2
Approx. 50°C
3/4
Approx. 40°C
1
5.2 Maintenance
5.1 Settings
5.1.1 Thermostat setting
The thermostat on the product is adjustable
from 60-90°C. The thermostat should not be
set lower than 65°C to prevent bacteria growth.
To adjust the temperature:
A) Disconnect the power supply.
B) Remove the covers (4) on the front with a
screwdriver.
C) Adjust the temperatures on the thermostat
(7) with a screwdriver.
Fit the covers (4) before connecting the power
supply. Changing the temperature setting on
the thermostats only changes the temperature
of the water in the tank. Temperature to the
taps is adjusted on the mixer valve.
5.1.2 Resetting the safety thermostat
The safety thermostat on the product cuts out
when there is a risk of overheating. This is reset
by removing the cover (4) and pressing the red
‘RESET’ button (6). If the thermostat cuts out re-
peatedly, contact the installer.
5.1.3 Setting the mixer valve
The outgoing hot water temperature from the
product to the taps in the home can be adjust-
ed with the knob on the mixer valve. To adjust
the temperature:
A) Turn the adjustable knob (1) all the way to ‘+’
B) Then turn the knob towards ‘-’ to the desired
temperature.
5.1.4 Adjusting the feet
The product is equipped with three factory-
fitted feet, adjustable from 0-40 mm. Screw the
feet out a minimum of 15 mm from the bottom
of the product. Adjust the feet individually un-
til the product is standing firmly vertically and
horizontally.
5. USER GUIDE
MAINTENANCE INSTRUCTIONS
!
Maintenance should be carried out by persons over 18 years of age, with
sufficient understanding
!
Annual inspection of safety valve:
- Open valve for 1 min. by turning the knob (3) approx. 90 degrees to the
open position.
- Visually check that the water is flowing freely to the drain.
- YES = OK. Close the valve by turning the knob (3) a further 90 degrees to
the closed position.
- NO = NOT OK. Disconnect power supply / shut off water supply. Contact installer.
3
RESET
RES
ET
M2
1
2
3
4
THERM-O-DISC
60°C
90°C
80°C
70°C
1
2
RESET
RES
ET
M2
1
2
3
4
THERM-O-DISC
60°C
90°C
80°C
70°C
1
2
7
6