9
RECOMMENDATION
!
Min. distance from ceiling to wall bracket is 35 cm to allow space for hanging. See diagram
under 3.4.
-
If the non-return valve is tight, a reduction valve and expansion vessel should be fitted (to
stop dripping from the safety valve).
-
If the maximum water pressure exceeds 6 bar in a 24-hour period, a reduction valve and
expansion vessel should be fitted.
-
For installation in a rooms which does not conform to the wetroom standard, a watertight
drip tray with overflow pipe
>
18 mm. inside diameter should be fitted under the product, in
addition to an automatic stop cock with sensor. This will prevent possible material damage.
3.5.5 Fitting instructions
3.5.6 Installation recommendation
!
CAUTION
!
The product should be placed in a room with a drain, in accordance with the wetroom
standard / latest TEK. Alternatively, fit an automatic stop valve with sensor and overflow
from safety valve to drain.
!
The product should be properly aligned vertically and horizontally. The product should
be fixed to a wall structure suitable for the total weight of the product when in operation.
!
The product must have a clearance for servicing of 40 cm in front of the cover / 10 cm
under the mixer valve.
!
WARNING
!
The product should be filled with water before the power is switched on.
!
Any overflow pipe from the safety valve MUST be >
15 mm, clear, undamaged and frost-
free with a fall to the drain.