background image

THANK YOU FOR CHOOSING FLUENCE!

Please confirm that all hardware and accessories received are correct for your 

VYPR application before you begin the installation. 

1. SYSTEM HARDWARE & ACCESSORIES 

.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  

2

1.1 Light Fixture and Power Supply   . . . . . . . . . . . . . . . . . . . . . . . . . .  2
1.2 Mounting Hardware  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
1.3 DC Power Extension Cables  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
1.4 DC Dimming Cables   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
1.5 AC Power Extension Cables  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

2. DIMENSIONS AND WEIGHT

.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .  

5

3. CAUTIONS AND WARNINGS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

5

4. IMPORTANT SAFETY PRECAUTIONS & EXPLANATIONS

 . . . . . . . . . . . . 

8

5. CULTIVATION BEST PRACTICE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

6. GENERAL CARE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

8

7. SYSTEM WIRING DIAGRAMS AND SPECIFICATIONS

.   .   .   .   .   .   .   .   .   .   .   .   .   .  

9

8. SYSTEM INSTALLATION INSTRUCTIONS

 . . . . . . . . . . . . . . . . . . . . .

10

9. MOUNTING INSTRUCTIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

9.1 Combo Mount Hanger Kit (Fixture and PSU2)  . . . . . . . . . . . . . . . . . . . 11
9.2 Perpendicular Mount Kit (Fixture)  . . . . . . . . . . . . . . . . . . . . . . . . . 11
9.3 Parallel Mount Kit (Fixture) .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 12
9.4 Unistrut Hanger Kit (Fixture and PSU2)   . . . . . . . . . . . . . . . . . . . . . . 13
9.5 Pipe Hanger Kit (Fixture and PSU2)   . . . . . . . . . . . . . . . . . . . . . . . . 13
9.6 Square Hanger Kit (Fixture and PSU2)  . . . . . . . . . . . . . . . . . . . . . . . 13
9.7 Combo Mount Hanger Kit (PSU2)   . . . . . . . . . . . . . . . . . . . . . . . . . 14
9.8 Power Supply Surface Mount Kits (PSU2)  . . . . . . . . . . . . . . . . . . . . . 15

10. PRODUCT GUARANTEE & WARRANTY

.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .

16

USER & INSTALLATION GUIDE

VYPR 3p

GLOBAL

© Copyright 2020 Fluence Bioengineering 2020-08 | Subject to change without notice

Summary of Contents for Fluence VYPR 3p

Page 1: ...8 5 CULTIVATION BEST PRACTICE 8 6 GENERAL CARE 8 7 SYSTEM WIRING DIAGRAMS AND SPECIFICATIONS 9 8 SYSTEM INSTALLATION INSTRUCTIONS 10 9 MOUNTING INSTRUCTIONS 11 9 1 Combo Mount Hanger Kit Fixture and...

Page 2: ...RIX FOR LIGHT FIXTURE AND POWER SUPPLY EUROPE FAMILY MODEL PhysioSpec SPECTRUM INPUT VOLTAGE PACKAGING VR VYPR 3P Gen 3 PLUS BP6 BP8 HR9 DR9 DR5 BROAD R6 BROAD R8 DUAL R9B High Efficacy DUAL R9B DUAL...

Page 3: ...eflector Kit 20 inch 2 Kits N A N A N A ARV3 10529 40 40 Kits N A N A N A ARV3 10529 10 10 Kits A B C D E F G H I Light Fixture Power Supply Mounting Light Fixture Mounting Power Supply Mounting Refle...

Page 4: ...Power Supply to AC Line EUROPE Quantity per Power Supply Ordering Code QTY Carton A 1 83m 6 FT AC Extension Cable VDE Schuko Type F7 plug 230V AC 1 pc CACE 70774 10 10 pcs B 1 83m 6 FT AC Extension Ca...

Page 5: ...the light source reached its end of life the whole luminaire shall be replaced Horticulture Lighting not suitable for household room illumination 1 PPF calculations compiled using integrating sphere m...

Page 6: ...felel szell z s t AVVERTENZA IT Rischio di elettrocuzione Per ridurre il rischio di lesioni gravi si raccomanda di prendere sempre le dovute precauzioni e scollegare l apparecchio prima di spostarlo o...

Page 7: ...musi vykona v sulade s narodnymi pravnymi predpismi SLO Identifikacija izdelka v smislu OEEO Ne zavrzite med gospodinjske odpadke Izdelek in embala o je treba med odpadke zavre i ustrezno in v skladu...

Page 8: ...their own techniques Every crop is different and everyone has different goals However our internal research has given us insight into several strategies we would like to share Regularly check your pla...

Page 9: ...upply CACE 71576 10 and CCA pigtail cable CACE 71650 10 CABLING A AC Power Ground B AC Power Neutral C AC Power Line Main D 0 10V DC Dim E 0 10V DC Dim Power Supply Connector Connector Type Pin Assign...

Page 10: ...O conecte primero la alimentaci n de CA ANTES de conectar la fuente de alimentaci n a la unidad VYPR Adem s los bordes de la aleta del disipador t rmico de la fuente de alimentaci n pueden ser afilado...

Page 11: ...cation per the installation steps for your purchased mounting hardware Hook each hanger end onto the upper loops at each corner of the power supply Take 2 more mounting hangers as shown and Insert the...

Page 12: ...en the cooling fins 3 3a 1a 2 3b 1b 3 9 3 Parallel Mount Kit AMV3 10571 20 Suitable for 25 mm x 50 mm T slotted strut Front View 3 3 84 mm Take 2 mounting hangers Hang both brackets on the support str...

Page 13: ...mm in diameter and for trusses or channel up to 2 3 4 69 9 mm wide IMPORTANT DO NOT mount the power supply vertically using wire form type hangers To mount the power supply vertically use a Surface M...

Page 14: ...2 2 3 3 4 1 1 Power Supply Remote with Unistrut Pipe or Square Hanger Kit Take 2 mounting brackets and hang a bracket over the support structure Locate the holes for brackets on the narrow side of PS...

Page 15: ...rt the weight of the power supply PSU2 LVG HVE PSU2 HVG 1 52 38 62 mm PS Height 1 52 38 62 mm PS Height Place one bracket behind the power supply end plate and align the screw holes Install a screw an...

Page 16: ...cts for five years from date of purchase Contact us at support fluencebioengineering com for more warranty information We stand behind our research we stand behind our technology and we stand behind o...