2.2
Open Enclosure
Loosen the thumbscrews that retain the top cover of the chassis and slide the lid towards you as shown below:
2.3
Install Expansion Interface Card
By default, the Expansion Interface card should already be installed in "SLOT 0-UPLINK” of the OSS Expansion board. It is set to “ON=EXP” and
configured as x16. User should not alter or change the settings of SW3. If you encounter problems, for troubleshooting purposes only check
SW3; verify the dipswitch is set to x16.
EB3450 comes with 1 Expansion Interface card. It is Gen3 x16; it has two available cable ports for linking either x8 or x16 connection.
If you need to replace or install the Expansion Interface card, follow the steps below:
1.
Check the dipswitch (SW4), make sure it is set to be “ON=EXP” position. See above picture.
2.
The chassis should be turned OFF.
3.
Install the new Expansion Interface card.