One Stop Systems
EB3450 | 57
The inrush current of power supply module is less than 120A under the conditions of 240Vrms input and 25oC ambient cold start.
The inrush current is limited to the extent that no damage will be done to the power supply under any specified line, load, and
temperature conditions.
The leakage current of the power supply module is less than 1.5 mA measured at 264Vac input.
The repetitive ON/OFF cycling of AC input voltage will not damage the power supply.
The power supply can automatically recover from AC power loss.
The power supply is equipped with primary fuse for input over-current protection, and meets product safety requirement.
3.8.3
DC Output
DC Output Voltage Regulations
The DC output voltages remain within the regulation ranges shown in Table 2 for both the power supply module and the completed power
system when measured at the load end of the output connectors under all AC line, O/P loads, and environmental conditions.
The remote sensing is provided to +12V, +5V, and +3.3V outputs to compensate for excessive cable drops.
+5V, +3.3V, and -12V outputs are located on the power distribution backplane.
3.8.4
DC Output Load Distributions
The Table 3 defines the power supply typical output load distribution.
a
) The total continuous output power is 750W~1200W max. For one (1) or two (2) modules installed.
b) The peak current of +12V output is 110% of max rated current and may last for 15 msec.
c) No minimum load is required to +5V, +3.3V, -12V and +5Vsb outputs.
DC Output Efficiency (power supply module)