One Stop Systems
EB3450 | 60
4 Express I/O Manager
4.1
Express I/O Management module
The Express I/O management subsystems consists of an Interface board for control interfacing to the EB 3450 and a NetBurner processor
module that provides control logic and simple Ethernet connectivity allowing you to have direct and quick access to control devices such as the
fan, power supply, and temperature and PCIe slots via the Web Management. The NetBurner is programmed with custom SNMP Web GUI for
managing and monitoring devices. Remote access is provided through a standard RJ-45 Ethernet connection at the rear panel.
4.2
Web Server and SNMP Features
EB3450 supports the Simple Network Management Protocol (SNMP) for remote monitoring and administration by offering the following
features:
Internal Temperature monitoring
Clear Alarm button monitoring
Power supply 1 status
Power supply 2 status
Traps are defined to alert the SNMP server in case of overheating or failure in any of the subsystems mentioned above
Remote chassis turn ON and turn Off
Remote Audible Alarm
Fan status
Fan speed control
4.3
Web Access and SNMP Configuration
To ensure that you can successfully monitor your new system, you will need to connect it to a local or private hub using a standard RJ-45
Ethernet Cable. To obtain access to the OSS chassis, direct your web browser to the given IP address:
192.168.1.10
. You must configure your
network on this same domain for this to work. Later, you can change the IP address to another domain or to use DHCP